Stationary Asset Energy Use
Available in: Lightning Experience |
Available in: Enterprise, Performance, Unlimited, and Developer Editions |
Permission Set Needed | |
---|---|
To enter and modify data: | Net Zero Cloud Manager OR Net Zero Cloud Admin |
Fuel Units | Electricity | Cooling | Diesel | Fuel Oil/Heavy Oil | Heat | Natural Gas | Liquid Natural Gas (LNG) | Propane | Steam | Light Oil | Kerosene | City Gas | Refrigerant |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
kWh | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
GWh | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
MWh | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
GJ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
MJ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
kcal | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
MMBtu | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
Therm | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
Kg | √ | ||||||||||||
lbs | √ | ||||||||||||
Tonnes | √ | ||||||||||||
Short Tons | √ | ||||||||||||
Long Tons | √ | ||||||||||||
US Gallon | √ | √ | √ | √ | √ | √ | √ | √ | |||||
UK Gallon | √ | √ | √ | √ | √ | √ | √ | √ | |||||
Liter | √ | √ | √ | √ | √ | √ | √ | √ | |||||
Kiloliters | √ | √ | √ | √ | √ | √ | √ | √ | |||||
m3 | √ | √ | √ | √ | √ | √ | √ | √ | |||||
1000 m3 | √ | √ | √ | √ | √ | √ | √ | √ | |||||
ccf | √ | √ | √ | √ | √ | √ | √ | √ |
Allocate the default scope for the fuel. Depending on the scope, the relevant fields are populated and the other fields default to 0:
- Scope 1 Emissions (tCO2e).
- Scope 2 Location-Based Emissions (tCO2e) and Scope 2 Market-Based Emissions (tCO2e). Scope 2 means both these fields are populated.
- Scope 3 Downstream Emissions (tCO2e).
- Scope 3 Upstream Emissions (tCO2e).
If you have not associated a scope allocation, then use the default scope allocations.
Fuel | Asset Owned | Asset Not Owned |
---|---|---|
Electricity | Scope 2 | Scope 2 |
City Gas | Scope 1 | Scope 2 |
Cooling | Scope 2 | Scope 2 |
Diesel | Scope 1 | Scope 2 |
Fuel Oil | Scope 1 | Scope 2 |
Heat | Scope 2 | Scope 2 |
Heavy Oil | Scope 1 | Scope 2 |
Kerosene | Scope 1 | Scope 2 |
Light Oil | Scope 1 | Scope 2 |
Liquid Natural Gas (LNG) | Scope 1 | Scope 2 |
Natural Gas | Scope 1 | Scope 2 |
Propane | Scope 1 | Scope 2 |
Refrigerant | Scope 1 | Scope 2 |
Steam | Scope 2 | Scope 2 |
IT Electricity | Scope 2 | Scope 2 |
Biomass | Scope 1 | Scope 2 |
For information about converting the values from one unit of measure to another compatible unit of measure, see Conversion Factors.
Here are the calculated fields:
-
Fuel Consumption (kWh) (FuelConsumptionInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
- Fuel Consumption (FuelConsumption)
- Other Emissions Factor Set (OtherEmssnFctrSet)
- Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
Fuel Type (FuelType)
Calorific Value (CalorificValue)
Calorific Value Unit (CalorificValueUnit)
- Conversion constant
Calculations
If these fuels are measured in volume units:
- City Gas
- Diesel
- Fuel Oil
- Heavy Oil
- Kerosene
- Light Oil
- Liquid Natural Gas (LNG)
- Natural Gas
- Propane
- Biomass
Then to convert the volume to energy units:
Fuel Consumption (kWh) = Fuel Consumption (converted to m3) × OtherEmssnFctrSet.OtherEmssnFctrSetItem.Calorific Value (converted to kWh/m3) and Fuel Type = OtherEmssnFctrSet.OtherEmssnFctrSetItem.Fuel Type
-
Fuel Consumption (GJ) (FuelConsumptionInGigajoule)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Conversion constant
Calculations
Fuel Consumption (GJ) = Total Fuel Consumption (kWh)/277.7777777
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
Input Fields
- Fuel Consumption (kWh) (FuelConsumptionInKwh)
- Power Usage Effectiveness (PowerUsageEffectiveness)
Calculations
If Record Type = "Data Center", then Total Fuel Consumption (kWh) = Fuel Consumption (kWh) × Power Usage Effectiveness.
else, for all other fuel types and record types, Total Fuel Consumption (kWh) = Fuel Consumption (kWh).
-
Occupied Floor Area (sqft) (OccupiedFloorAreaInSqft)
Input Fields
- Occupied Floor Area (OccupiedFloorArea)
- Occupied Floor Area Unit (OccupiedFloorAreaUnit)
- Conversion constant
External Object Calculations
If Occupied Floor Area Unit = "sqft", then Occupied Floor Area (sqft) = Occupied Floor Area.
If Occupied Floor Area Unit = "m2", then Occupied Floor Area (sqft) = Occupied Floor Area × 10.76391042.
-
Scope 1 Emissions (tCO2e) (Scope1EmissionsInTco2e)
Input Fields
- Other Emissions Factors (OtherEmssnFctrId)
- Supplemental Scope 1 Emissions (SuplScope1Emissions)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
Calculations
- If the scope allocation for a fuel is scope 1, then StnryAssetEnvrSrc.Carbon Emissions Scope Allocation.Fuel Type Allocation = "Scope 1" where StnryAssetEnvrSrc.CrbnEmssnScopeAlloc.FuelType = FuelType.
- If Fuel Type = "Electricity", then Scope 1 Emissions (tCO2e) = (Total Fuel Consumption (kWh)) × ElectricityEmssnFctrSet.CO2e Emissions Rate (tonnes/MWh)/1000 + Supplemental Scope 1 Emissions.
- For any fuel other than refrigerants and electricity,
If (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor = 0) then Scope 1 Emissions (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.CO2e Emissions Factor (tCO2e/MWh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 1 Emissions
else if (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor != 0) then Scope 1 Emissions (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor (convert to Kg/Kwh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 1 Emissions.
- If FuelType = "Refrigerant", then Scope 1 Emissions (tCO2e) = FuelConsumption (converted to Kgs) × RefrigerantEmssnFctr.Global Warming Potential/1000 + Supplemental Scope 1 Emission
Default Value
Scope 1 Emissions (tCO2e) = Supplemental Scope 1 Emissions
-
Scope 2 Location-Based Emission (tCO2e) (Scope2LocBasedEmssnInTco2e)
Input Fields
- Other Emissions Factors (OtherEmssnFctrId)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factors (ElectricityEmissionFactorsId)
- Company-Owned Asset (IsCompanyOwnedAsset)
- Supplemental Scope 2 Location-Based Emissions (SuplScope2LocationBasedEmssn)
Calculations
- StnryAssetEnvrSrc.Carbon Emission Scope Allocation Value.Fuel Type Allocation = "Scope 2" ( where StnryAssetEnvrSrc.Carbon Emission Scope Allocation Value.Fuel Type = Fuel Type )
- If Fuel Type = "Electricity" then Scope 2 Location-Based Emission (tCO2e) =(Total Fuel Consumption (kWh) ) × Electricity Emissions Factor Set.Co2eEmissionRateInTmwh / 1000 + SuplScope2LocationBasedEmssn
- For any fuel other than refrigerants & Electricity
If (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor = 0) then Scope 2 Location-Based Emission (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.CO2e Emissions Factor (tCO2e/MWh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Location-Based Emissions
else if (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor != 0) then Scope 2 Location-Based Emission (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor (convert to Kg/Kwh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Location-Based Emissions
- If Fuel Type="Refrigerant" then Scope 2 Location-Based Emission (tCO2e) = Fuel Consumption (converted to Kgs) × RefrigerantEmssnFctr.Global Warming Potential/1000 + Supplemental Scope 2 Location-Based Emissions
Default Value
Scope 2 Location-Based Emission (tCO2e) = Supplemental Scope 2 Location-Based Emissions
-
Scope 2 Market-Based Emission (tCO2e) (Scope2MktBasedEmssnInTco2e)
Input Fields
- Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
- Company-Owned Asset (IsCompanyOwnedAsset)
- Electricity Emissions Factors (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
- Supplemental Scope 2 Market-Based Emissions (SuplScope2MarketBasedEmssn)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
- Energy Attribute Certificate Credit (EnergyAttrCertCredit)
- Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
- Clean Energy Project (CleanEnergyProject)
Calculations
StnryAssetEnvrSrc.Carbon Emission Scope Allocation Value.Fuel Type Allocation = "Scope 2" ( where StnryAssetEnvrSrc.Carbon Emission Scope Allocation Value.Fuel Type = Fuel Type)
- If Renewable Energy Type Override ! = Empty, then Scope 2 Market-Based Emissions
(tCO2e) = ((Total Fuel Consumption (kWh) - Allocated Renewable Energy Override (kWh) ) ×
(if Market-Based Electricity Emissions Factors != Empty
(MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000))
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None) (MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000))
else 0))
When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object,
if Renewable Energy Type Override == Empty (None),
then Scope 2 Market-Based Emissions (tCO2e) =(Total Fuel Consumption (kWh) - Allocated Energy Attribute Credits (kWh)] ) × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000)))
else if (MktBsdElectriEmssnFctrId.Emissions Factor Type == LocationAndMarketBased or None) (MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000))
else 0+ Supplemental Scope 2 Market-Based Emissions) + for each Energy Attribute Credit Distribution associated with this record if (EnergyAttrCreditDstr.EnergyAttrCertPurchase.CleanEnergyProject.Electricity Emissions Factors !=NULL (EnergyAttrCreditDstr.Allocated Energy Attribute Credits (kWh) × EnergyAttrCreditDstr.EnergyAttrCertPurchase.CleanEnergyProject.ElectrEmissionsFactorsId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000))
- For any fuel other than refrigerants and Electricity
If (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor = 0) then Scope 2 Market-Based Emissions (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.CO2e Emissions Factor (tCO2e/MWh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Market-Based Emissions
else if (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor != 0) then Scope 2 Market-Based Emissions (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor (convert to Kg/Kwh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Market-Based Emissions
- If FuelType="Refrigerant", Scope 2 Market-Based Emissions (tCO2e) = Fuel Consumption (converted to Kgs) × RefrigerantEmssnFctr.Global Warming Potential/1000 + Supplemental Scope 2 Market-Based Emissions
Default Value
Scope 2 Market-Based Emission (tCO2e) = Supplemental Scope 2 Market-Based Emissions
-
Market-Based CO2 Emissions (kg) (MktBsdCo2EmssnInKg)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
- Other Emissions Factor Set (OtherEmssnFctrSet)
- Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
- Fuel Type (FuelType)
- CO2 Emissions Factor (Co2EmissionFactor)
- CO2 Emissions Factor Unit (Co2EmissionFactorUnit)
- Electricity Emissions Factors (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
- Energy Attribute Certificate Credit (EnergyAttrCertCredit)
- Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
- Clean Energy Project (CleanEnergyProject)
- Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
Calculations
If (Fuel Type == REFRIGERANT) {
then Market-Based CO2 Emissions (kg) = 0;
} Else if (Fuel Type == ELECTRICITY) {
If (Renewable Energy Type Override!= Empty) {
Market-Based CO2 Emissions (kg) = (Total Fuel Consumption (kWh) TotalFuelConsumptionInKwh - Allocated Renewable Energy Override (kWh)) * ElectricityEmssnFctrSet.Market-Based CO2 Emissions Rate (tonnes/MWh)
} else {
Market-Based CO2 Emissions (kg) = (Total Fuel Consumption (kWh) * ElectricityEmssnFctrSet.Market-Based CO2 Emissions Rate (tonnes/MWh))
}
} Else { // Default calculation for all other fuel types
Market-Based CO2 Emissions (kg) = (Total Fuel Consumption (kWh) * OtherEmssnFctrSetItem.CO2 Emissions Factor * OtherEmssnFctrSetItem.CO2 Emissions Factor Unit converted to Kg per KWh
}
-
Market-Based CH4 Emissions (kg) (MktBsdCh4EmssnInKg)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
- Other Emissions Factor Set (OtherEmssnFctrSet)
- Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
- Fuel Type (FuelType)
- CH4 Emissions Factor (Ch4EmissionFactor)
- CH4 Emissions Factor Unit (Ch4EmissionFactorUnit)
- Electricity Emission Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based CH4 Emissions Rate (tonnes/GWh) (MktBsdCh4EmssnRtInTgwh)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based CH4 Emissions Rate (tonnes/GWh) (MktBsdCh4EmssnRtInTgwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
- Stationary Asset Energy Use (StnryAssetEnergyUseId)
- Energy Attribute Certificate Credit (EnergyAttrCertCredit)
- Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
- Clean Energy Project (CleanEnergyProject)
- Electricity Emissions Factors (ElectrEmissionsFactorsId)
Market-Based CH4 Emissions Rate (tonnes/GWh) (MktBsdCh4EmssnRtInTgwh)
- Electricity Emissions Factors (ElectrEmissionsFactorsId)
Calculations
If (Fuel Type == REFRIGERANT) {
then Market-Based CH4 Emissions (kg) = 0;
} Else if (Fuel Type == ELECTRICITY) {
If (Renewable Energy Type Override!= Empty) {
Market-Based CH4 Emissions (kg) = (Total Fuel Consumption (kWh) TotalFuelConsumptionInKwh - Allocated Renewable Energy Override (kWh)) * ElectricityEmssnFctrSet.Market-Based CH4 Emissions Rate (tonnes/GWh)/1000.0
} else {
Market-Based CH4 Emissions (kg) = Total Fuel Consumption (kWh) * ElectricityEmssnFctrSet.Market-Based CH4 Emissions Rate (tonnes/GWh)/1000.0
}
} Else { // Default calculation for all other fuel types
Market-Based CH4 Emissions (kg) = (Total Fuel Consumption (kWh) * OtherEmssnFctrSetItem.CH4 Emissions Factor * OtherEmssnFctrSetItem.CH4 Emissions Factor Unit converted to Kg per KWh
}
-
Market-Based N2O Emissions (kg) (MktBsdN2oEmssnInKg)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
- Other Emissions Factor Set (OtherEmssnFctrSet)
- Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
- Fuel Type (FuelType)
- N2O Emissions Factor (N2oEmissionFactor)
- N2O Emissions Factor Unit (N2oEmissionFactorUnit)
- Electricity Emission Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based N2O Emissions Rate (tonnes/GWh) (MktBsdN2oEmssnRtInTgwh)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based N2O Emissions Rate (tonnes/GWh) (MktBsdN2oEmssnRtInTgwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
- Stationary Asset Energy Use (StnryAssetEnergyUseId)
- Energy Attribute Certificate Credit (EnergyAttrCertCredit)
Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
- Clean Energy Project (CleanEnergyProject)
- Electricity Emissions Factors (ElectrEmissionsFactorsId)
- Market-Based N2O Emissions Rate (tonnes/GWh) (MktBsdN2oEmssnRtInTgwh)
Calculations
If (Fuel Type == REFRIGERANT) {
then Market-Based N2O Emissions (kg) = 0;
} Else if (Fuel Type == ELECTRICITY) {
If (Renewable Energy Type Override!= Empty) {
Market-Based N2O Emissions (kg) = (Total Fuel Consumption (kWh) TotalFuelConsumptionInKwh - Allocated Renewable Energy Override (kWh)) * ElectricityEmssnFctrSet.Market-Based N2O Emissions Rate (tonnes/GWh)/1000.0
} else {
Market-Based N2O Emissions (kg) = (Total Fuel Consumption (kWh) * ElectricityEmssnFctrSet.Market-Based N2O Emissions Rate (tonnes/GWh)/1000.0)
}
} Else { // Default calculation for all other fuel types
Market-Based N2O Emissions (kg) = (Total Fuel Consumption (kWh) * OtherEmssnFctrSetItem.N2O Emissions Factor * OtherEmssnFctrSetItem.N2O Emissions Factor Unit converted to Kg per KWh
}
-
Total Floor Area (sqft) (TotalFloorAreaInSqft)
Input Fields
- Total Floor Area (TotalFloorArea)
- Total Floor Area Unit (TotalFloorAreaUnit)
- Conversion constant
External Object Calculations
If Total Floor Area Unit = "sqft", then Total Floor Area (sqft) = Total Floor Area.
If Total Floor Area Unit = "m2", then Total Floor Area (sqft) = Total Floor Area × 10.76391042.
-
Total Renewable Energy (kWh) (TotalRenewableEnergyInKwh)
Input Fields
- Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
- Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)
- Market-Based Electricity from Hydro (kWh) (MktBasedElectrFromHydroInKwh)
- Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
- Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)
Calculations
Total Renewable Energy (kWh) = Market-Based Electricity from Biomass (kWh) + Market-Based Electricity from Geothermal (kWh) + Market-Based Electricity from Hydro (kWh) + Market-Based Electricity from Solar (kWh) + Market-Based Electricity from Wind (kWh)
Default Value
0
-
Total Renewable Energy Excluding Hydro (kWh)
(TotRnwlEnrgyExclHydroInKwh)
Input Fields
- Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
- Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)
- Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
- Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)
Calculations
Total Renewable Energy Excluding Hydro (kWh) = Market-Based Electricity from Biomass (kWh) + Market-Based Electricity from Geothermal (kWh) + Market-Based Electricity from Solar (kWh) + Market-Based Electricity from Wind (kWh)
Default Value
0
-
Power Usage Effectiveness Monthly Range (IsPueMonthlyRange)
Input Fields
- Power Usage Effectiveness (PowerUsageEffectiveness)
- Record Type
Calculations
If Record Type = "Data Center":
If Power Usage Effectiveness >= 1 and Power Usage Effectiveness <= 2, then Power Usage Effectiveness Monthly Range = TRUE.
If Power Usage Effectiveness <1 or Power Usage Effectiveness > 2, then Power Usage Effectiveness Monthly Range = FALSE.
-
Normalized Monthly Electricity Consumption (kWh)
(NormalizedMoElectrCnsmpInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
- End Date (EndDate)
- Start Date (StartDate)
Calculations
Normalized Monthly Electricity Consumption (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × [30/(End Date – Start Date + 1)]
-
Location-Based Electricity from Biomass (kWh)
(LocBasedElectrFrBiomassInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Biomass Mix Percentage (ElectricityEmssnFctrSet.LocationBasedBiomassMixPct)
Calculations
Location-Based Electricity from Biomass (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Biomass Mix Percentage/100
-
Location-Based Electricity from Coal (kWh) (LocBasedElectrFrCoalInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Coal Mix Percentage (ElectricityEmssnFctrSet.LocationBasedCoalMixPct)
Calculations
Location-Based Electricity from Coal (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Coal Mix Percentage/100
-
Location-Based Electricity from Gas (kWh) (LocBasedElectrFrGasInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Gas Mix Percentage (ElectricityEmssnFctrSet.LocationBasedGasMixPct)
Calculations
Location-Based Electricity from Gas (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Gas Mix Percentage/100
-
Location-Based Electricity from Hydro (kWh)
(LocBasedElectrFrHydroInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Hydro Mix Percentage (ElectricityEmssnFctrSet.LocationBasedHydroMixPct)
Calculations
Location-Based Electricity from Hydro (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Hydro Mix Percentage/100
-
Location-Based Electricity from Nuclear (kWh)
(LocBasedElectrFrNuclearInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Nuclear Mix Percentage (ElectricityEmssnFctrSet.LocationBasedNuclearMixPct)
Calculations
Location-Based Electricity from Nuclear (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × Electricity Emissions Factor Set.Location-Based Nuclear Mix Percentage/100
-
Location-Based Electricity from Oil (kWh) (LocBasedElectrFrOilInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Oil Mix Percentage (ElectricityEmssnFctrSet.LocationBasedOilMixPct)
Calculations
Location-Based Electricity from Oil (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × ElectricityEmssnFctrSet.Location-Based Oil Mix Percentage/100
-
Location-Based Electricity from Other Fuel (kWh)
(LocBasedElectrFrOthrFuelInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Other Fuel Mix Percentage (ElectricityEmssnFctrSet.LocationBasedOtherFuelMixPct)
Calculations
Location-Based Electricity from Other Fuel (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Other Fuel Mix Percentage/100
-
Location-Based Electricity from Solar (kWh)
(LocBasedElectrFrSolarInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Solar Mix Percentage (ElectricityEmssnFctrSet.LocationBasedSolarMixPct)
Calculations
Location-Based Electricity from Solar (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Solar Mix Percentage/100
-
Location-Based Electricity from Wind (kWh) (LocBasedElectrFrWindInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Wind Mix Percentage (ElectricityEmssnFctrSet.LocationBasedWindMixPct)
Calculations
Location-Based Electricity from Wind (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Wind Mix Percentage/100
-
Location-Based Electricity from Non-Renewables (kWh)
(LocBsdElectrFrNonRenewablesKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Location-Based Electricity from Biomass (kWh) (LocBasedElectrFrBiomassInKwh)
- Location-Based Electricity from Hydro (kWh) (LocBasedElectrFromHydroInKwh)
- Location-Based Electricity from Solar (kWh) (LocBasedElectrFromSolarInKwh)
- Location-Based Electricity from Wind (kWh) (LocBasedElectrFromWindInKwh)
- Location-Based Electricity from Geothermal (kWh) (LocBsdElectrFrGeothermalInKwh)
Calculations
Location-Based Electricity from Non-Renewable (kWh) = Total Fuel Consumption (kWh) – Location-Based Electricity from Biomass (kWh) – Location-Based Electricity from Hydro (kWh) – Location-Based Electricity from Solar (kWh) – Location-Based Electricity from Wind (kWh) – Location-Based Electricity from Geothermal (kWh)
-
Location-Based Electricity from Geothermal (kWh)
(LocBsdElectrFrGeothermalInKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Geothermal Mix Percentage (ElectricityEmssnFctrSet.LocBasedGeothermalMixPct)
Calculations
Location-Based Electricity from Geothermal (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × ElectricityEmssnFctrSet.Location-Based Geothermal Mix Percentage/100
-
Location-Based Electricity from Other Fossil Fuel (kWh)
(LocBsdElectrOthrFossilFuelKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Electricity Emissions Factor Set.Location-Based Other Fossil Fuel Mix Percentage (ElectricityEmssnFctrSet.LocBasedOtherFossilFuelMixPct)
Calculations
Location-Based Electricity from Other Fossil Fuel (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × ElectricityEmssnFctrSet.Location-Based Other Fossil Fuel Mix Percentage/100
-
Market-Based Electricity from Biomass (kWh)
(MktBasedElectrFrBiomassInKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Allocated Energy Attribute Credits from Biomass (kWh) (AllocEnrgyAttrCrBiomass)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Biomass Mix Percentage (MarketBasedBiomassMixPct)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Biomass Mix Percentage (MarketBasedBiomassMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
- Stationary Asset Energy Use (StnryAssetEnergyUseId)
- Energy Attribute Certificate Credit (EnergyAttrCertCredit)
- Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
Calculations
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from
Biomass (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") –
Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors !=
Empty (MktBsdElectriEmssnFctr.Market-Based Biomass Mix Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Biomass Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute Credit
Distribution object, if Renewable Energy Type Override == Empty (None), then
Market-Based Electricity from Biomass (kWh) = [Total Fuel Consumption (kWh) (where
FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based
Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctr.Market-Based Biomass Mix
Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Biomass Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Market-Based Electricity from Coal (kWh) (MktBasedElectrFromCoalInKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Coal Mix Percentage (MarketBasedCoalMixPct)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Coal Mix Percentage (MarketBasedCoalMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
Calculations
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Coal
(kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated
Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty
(MktBsdElectriEmssnFctrId.Market-Based Coal Mix Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Coal Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute Credit
Distribution object, if Renewable Energy Type Override == Empty (None), then
Market-Based Electricity from Coal (kWh) = [Total Fuel Consumption (kWh) (where FuelType
= "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based
Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Coal Mix
Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Coal Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Market-Based Electricity from Gas (kWh) (MktBasedElectrFromGasInKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Gas Mix Percentage (MarketBasedGasMixPct)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Gas Mix Percentage (MarketBasedGasMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
- Stationary Asset Energy Use (StnryAssetEnergyUseId)
- Energy Attribute Certificate Credit (EnergyAttrCertCredit)
- Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
Calculations
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Gas
(kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated
Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty
(MktBsdElectriEmssnFctrId.Market-Based Gas Mix Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Gas Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute
Credit Distribution object,
if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Gas (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Gas Mix Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Gas Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Market-Based Electricity from Hydro (kWh)
(MktBasedElectrFromHydroInKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Hydroelectric Mix Percentage (MarketBasedHydroMixPct)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Hydroelectric Mix Percentage (MarketBasedHydroelectricMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
Calculations
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Hydro
(kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated
Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty
(MktBsdElectriEmssnFctrId.Market-Based Hydro Mix Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Hydro Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute Credit
Distribution object, if Renewable Energy Type Override == Empty (None), then
Market-Based Electricity from Hydro (kWh) = [Total Fuel Consumption (kWh) (where
FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based
Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Hydro Mix
Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Hydro Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Market-Based Electricity from Nuclear (kWh)
(MktBasedElectrFrNuclearInKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Nuclear Mix Percentage (MarketBasedNuclearMixPct)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Nuclear Mix Percentage (MarketBasedNuclearMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
Calculations
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from
Nuclear (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") –
Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors !=
Empty (MktBsdElectriEmssnFctrId.Market-Based Nuclear Mix Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Nuclear Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute Credit
Distribution object, if Renewable Energy Type Override == Empty (None), then
Market-Based Electricity from Nuclear (kWh) = [Total Fuel Consumption (kWh) (where
FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based
Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Nuclear
Mix Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Nuclear Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Market-Based Electricity from Oil (kWh) (MktBasedElectrFromOilInKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Oil Mix Percentage (MarketBasedOilMixPct)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Oil Mix Percentage (MarketBasedOilMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
Calculations
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Oil
(kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated
Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty
(MktBsdElectriEmssnFctrId.Market-Based Oil Mix Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Oil Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute Credit
Distribution object, if Renewable Energy Type Override == Empty (None), then
Market-Based Electricity from Oil (kWh) = [Total Fuel Consumption (kWh) (where FuelType
= "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based
Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Oil Mix
Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Oil Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Market-Based Electricity from Other Fuel (kWh)
(MktBasedEnrgyFromOthrFuelInKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Other Fuel Mix Percentage (MarketBasedOtherFuelMixPct)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Other Fuel Mix Percentage (MarketBasedOtherFuelMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
Calculations
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity
from Other Fuel (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity")
– Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors !=
Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fuel Mix Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Other Fuel Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute
Credit Distribution object, if Renewable Energy Type Override == Empty (None), then
Market-Based Electricity from Other Fuel (kWh) = [Total Fuel Consumption (kWh) (where
FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based
Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fuel
Mix Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Other Fuel Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Market-Based Electricity from Solar (kWh) (MktBasedEnrgyFromSolarInKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Allocated Energy Attribute Credits from Solar (kWh) (AllocEnrgyAttrCrSolar)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Solar Mix Percentage (MarketBasedSolarMixPct)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Solar Mix Percentage (MarketBasedSolarMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
Calculations
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity
from Solar (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") –
Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors !=
Empty (MktBsdElectriEmssnFctrId.Market-Based Solar Mix Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Solar Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute
Credit Distribution object, if Renewable Energy Type Override == Empty (None), then
Market-Based Electricity from Solar (kWh) = [Total Fuel Consumption (kWh) (where
FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based
Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Solar Mix
Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Solar Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Market-Based Electricity from Wind (kWh) (MktBasedEnrgyFromWindInKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Allocated Energy Attribute Credits from Wind (kWh) (AllocEnrgyAttrCrWind)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Wind Mix Percentage (MarketBasedWindMixPct)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Wind Mix Percentage (MarketBasedWindMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
Calculations
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Wind
(kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated
Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty
(MktBsdElectriEmssnFctrId.Market-Based Wind Mix Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Wind Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute Credit
Distribution object, if Renewable Energy Type Override == Empty (None), then
Market-Based Electricity from Wind (kWh) = [Total Fuel Consumption (kWh) (where FuelType
= "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based
Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Wind Mix
Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Wind Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Market-Based Electricity from Non-Renewables (kWh)
(MktBsdEnrgyFrNonRenewablesKwh)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
- Market-Based Electricity from Hydro (kWh) (MktBasedElectrFromHydroInKwh)
- Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
- Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)
- Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)
Calculations
Market-Based Electricity from Non-Renewables (kWh) = Total Fuel Consumption (kWh) – Market-Based Electricity from Biomass (kWh) – Market-Based Electricity from Hydro (kWh) – Market-Based Electricity from Solar (kWh) – Market-Based Electricity from Wind (kWh) – Market-Based Electricity from Geothermal (kWh)
-
Market-Based Electricity from Geothermal (kWh)
(MktBsdEnrgyFromGeothermalInKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Allocated Energy Attribute Credits from Geothermal (kWh) (AllocEnrgyAttrCrGeothermal)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmssnFctrSet)
- Market-Based Geothermal Mix Percentage (MktBasedGeothermalMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
Calculations
- If Renewable Energy Type = "Geothermal", then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100 + Allocated Renewable Energy (kWh)
- If Renewable Energy Type ! = "Geothermal" && !Empty, then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100
- When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type == Empty (None), then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Energy Attribute Credits (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100 + Allocated Energy Attribute Credits from Geothermal (kWh)
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity
from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity")
– Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors !=
Empty (MktBsdElectriEmssnFctrId.Market-Based Geothermal Mix Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Geothermal Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute
Credit Distribution object, if Renewable Energy Type Override == Empty (None), then
Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where
FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based
Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Geothermal
Mix Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Geothermal Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Market-Based Electricity from Other Fossil Fuel (kWh)
(MktBsdElectrOthrFossilFuelKwh)
Input Fields
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
- Renewable Energy Type Override (RenewableEnergyType)
- Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
- Allocated Energy Attribute Credits from Geothermal (kWh) (AllocEnrgyAttrCrGeothermal)
- Fuel Type (FuelType)
- Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Other Fossil Fuel Mix Percentage (MktBasedOtherFossilFuelMixPct)
- Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
- Emissions Factor Type (EmissionsFactorType)
- Market-Based Other Fossil Fuel Mix Percentage (MktBasedOtherFossilFuelMixPct)
- Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
Calculations
- If Renewable Energy Type Override ! = Empty, then Market-Based Electricity
from Other Fossil Fuel (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type =
"Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity
Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fossil Fuel Mix
Percentage)
else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Other Fossil Fuel Mix Percentage))
else 0
- When the renewable energy allocation is happening from the Energy Attribute
Credit Distribution object, if Renewable Energy Type Override == Empty (None), then
Market-Based Electricity from Other Fossil Fuel (kWh) = [Total Fuel Consumption (kWh)
(where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if
Market-Based Electricity Emissions Factors != Empty
(MktBsdElectriEmssnFctrId.Market-Based Other Fossil Fuel Mix Percentage)
else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Other Fossil Fuel Mix Percentage))
else 0
- Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
Input Fields
- Allocated Energy Attribute Credits from Biomass (kWh) (AllocEnrgyAttrCrBiomassNumber)
- Allocated Energy Attribute Credits from Geothermal (kWh) (AllocEnrgyAttrCrGeothermalNumber)
- Allocated Energy Attribute Credits from Solar (kWh) (AllocEnrgyAttrCrSolarNumber)
- Allocated Energy Attribute Credits from Wind (kWh) (AllocEnrgyAttrCrWind)
Calculations
Allocated Energy Attribute Credits (kWh) = Allocated Energy Attribute Credits from Biomass (kWh) + Allocated Energy Attribute Credits from Geothermal (kWh) + Allocated Energy Attribute Credits from Wind (kWh) + Allocated Energy Attribute Credits from Solar (kWh)
-
Scope 3 Downstream Emissions (tCO2e) (Scope3DnstrmEmissionsIntCO2e)
Input Fields
- Other Emissions Factors (OtherEmissionFactors)
- Supplemental Scope 3 Downstream Emissions (SuplScope3DnstrmEmissions)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Stationary Asset Environmental Source (StnryAssetEnvrSrc)
- Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)
Calculations
If(StnryAssetEnvrSrc.CrbnEmssnScopeAlloc.CrbnEmssnScopeAllocVal.FuelTypeAllocation value is one of these values
- Scope 3 Downstream
- Scope 3 Downstream Leased Assets
- Scope 3 End-of-Life Treatment of Sold Products
- Scope 3 Franchises
- Scope 3 Investments
- Scope 3 Processing of Sold Products
- Scope 3 Use of Sold Products
Then see the calculations for Scope 1 Emissions (tCO2e)
Default Value
Scope3DnstrmEmissionsIntCO2e = SuplScope3DnstrmEmissions
-
Scope 3 Upstream Emissions (tCO2e) (Scope3UpstrmEmissionsInTco2e)
Input Fields
- Other Emissions Factors (OtherEmissionFactors)
- Supplemental Scope 3 Upstream Emissions (SuplScope3UpstrmEmissions)
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Stationary Asset Environmental Source (StnryAssetEnvrSrc)
Calculations
If(StnryAssetEnvrSrc.CrbnEmssnScopeAlloc.CrbnEmssnScopeAllocVal.FuelTypeAllocation value is one of these values
- Scope 3 Upstream
- Scope 3 Capital Goods
- Scope 3 Employee Commuting
- Scope 3 Fuel and Energy-Related Activities
- Scope 3 Purchased Goods and Services
- Scope 3 Upstream Leased Assets
- Scope 3 Waste Generated In Operations
Then see the calculations for Scope 1 Emissions (tCO2e)
Default Value
Scope 3 Upstream Emissions (tCO2e) = Supplemental Scope 3 Upstream Emissions
-
Scope 3 GHG Category (Scope3GhgCategory)
Input Fields
- Stationary Asset Environmental Source (StnryAssetEnvrSrc)
- Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)
Calculations
If(StnryAssetEnvrSrc.CrbnEmssnScopeAlloc.CrbnEmssnScopeAllocVal.FuelTypeAllocation value is one of these values
- Scope 3 Purchased Goods and Services
- Scope 3 Capital Goods
- Scope 3 Processing of Sold Products
- Scope 3 Upstream Leased Assets
- Scope 3 Fuel and Energy-Related Activities
- Scope 3 Employee Commuting
- Scope 3 End-of-Life Treatment of Sold Products
- Scope 3 Waste Generated In Operations
- Scope 3 Use of Sold Products
- Scope 3 Downstream Leased Assets
- Scope 3 Investments
- Scope 3 Franchises
then
Scope 3 GHG Category = CrbnEmssnScopeAllocVal.FuelTypeAllocation
else
Scope 3 GHG Category = null
-
CH4 Emissions (kg) (Ch4EmissionsInKg)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
- Other Emissions Factor Set (OtherEmssnFctrSet)
- Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
Fuel Type (FuelType)
CH4 Emissions Factor (Ch4EmissionFactor)
- Electricity Emission Factor Set (ElectricityEmssnFctrSet)
CH4 Emissions Rate (tonnes/GWh) (Ch4EmissionRateInTgwh)
Calculations
If Fuel Type = "Electricity"
- CH4 Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.CH4 Emissions Rate (tonnes/GWh) × 1000/1000000.0
Default = 0
For any fuel other than refrigerants and electricity
- If CH4 Emissions Factor is in energy units
CH4 Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.CH4 Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.CH4 Emissions Factor is converted to Kg/Kwh
- else CH4 Emissions (kg) = 0
-
CO2 Emissions (kg) (Co2EmissionsInKg)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
- Other Emissions Factor Set (OtherEmssnFctrSet)
- Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
Fuel Type (FuelType)
CO2 Emissions Factor (Co2EmissionFactor)
- Electricity Emission Factor Set (ElectricityEmssnFctrSet)
CO2 Emissions Rate (tonnes/MWh) (Co2EmissionRateInTmwh)
Calculations
If Fuel Type = "Electricity"
- CO2 Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.CO2 Emissions Rate (tonnes/MWh) × 1000/1000.0
Default = 0
For any fuel other than refrigerants and electricity
- If CO2 Emissions Factor is in energy units
CO2 Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.CO2 Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.CO2 Emissions Factor is converted to Kg/Kwh
- else CO2 Emissions (kg) = 0
-
N2O Emissions (kg) (N2oEmissionsInKg)
Input Fields
- Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
- Other Emissions Factor Set (OtherEmssnFctrSet)
- Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
Fuel Type (FelType)
N2O Emissions Factor (N2oEmissionFactor)
- Electricity Emission Factor Set (ElectricityEmssnFctrSet)
N2O Emissions Rate (tonnes/GWh) (N2oEmissionRateInTgwh)
Calculations
If Fuel Type = "Electricity"
- N2O Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.N2O Emissions Rate (tonnes/GWh) × 1000/1000000.0
Default = 0
For any fuel other than refrigerants and electricity
- If N2O Emissions Factor is in energy units
N2O Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.N2O Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.N2O Emissions Factor is converted to Kg/Kwh
- else N2O Emissions (kg) = 0
-
Fuel Consumption
Inputs
- Occupied Floor Area (OccupiedFloorArea)
- Occupied Floor Area Unit (OccupiedFloorAreaUnit)
- Other Emission Factors (OtherEmissionFactors)
- Refrigerant Leakage Rate (kg/sqft) (RefrigerantLeakageRtInKgSqft)
Calculations
If (Fuel Type = "Refrigerant") and Fuel Consumption is NULL
then
Fuel Consumption = Occupied Floor Area (converted to sqft) × OtherEmissionFactors.Refrigerant Leakage Rate (kg/sqft)