Stationary Asset Energy Use

The Stationary Asset Energy Use object represents the energy consumption related to stationary assets across multiple fuel types.

Permission Set Needed
To enter and modify data: Net Zero Cloud Manager

OR

Net Zero Cloud Admin

Table 1. Fuel Consumption (kWh) Units by Fuel Type
Fuel Units Electricity Cooling Diesel Fuel Oil/Heavy Oil Heat Natural Gas Liquid Natural Gas (LNG) Propane Steam Light Oil Kerosene City Gas Refrigerant
kWh √ √ √ √ √ √ √ √ √ √ √ √
GWh √ √ √ √ √ √ √ √ √ √ √ √
MWh √ √ √ √ √ √ √ √ √ √ √ √
GJ √ √ √ √ √ √ √ √ √ √ √ √
MJ √ √ √ √ √ √ √ √ √ √ √ √
kcal √ √ √ √ √ √ √ √ √ √ √ √
MMBtu √ √ √ √ √ √ √ √ √ √ √ √
Therm √ √ √ √ √ √ √ √ √ √ √ √
Kg √
lbs √
Tonnes √
Short Tons √
Long Tons √
US Gallon √ √ √ √ √ √ √ √
UK Gallon √ √ √ √ √ √ √ √
Liter √ √ √ √ √ √ √ √
Kiloliters √ √ √ √ √ √ √ √
m3 √ √ √ √ √ √ √ √
1000 m3 √ √ √ √ √ √ √ √
ccf √ √ √ √ √ √ √ √

Allocate the default scope for the fuel. Depending on the scope, the relevant fields are populated and the other fields default to 0:

  • Scope 1 Emissions (tCO2e).
  • Scope 2 Location-Based Emissions (tCO2e) and Scope 2 Market-Based Emissions (tCO2e). Scope 2 means both these fields are populated.
  • Scope 3 Downstream Emissions (tCO2e).
  • Scope 3 Upstream Emissions (tCO2e).

If you have not associated a scope allocation, then use the default scope allocations.

Fuel Company-Owned Asset = Yes Company-Owned Asset = No
Electricity Scope 2 Scope 3 Upstream Leased Assets
City Gas Scope 1 Scope 3 Upstream Leased Assets
Cooling Scope 2 Scope 3 Upstream Leased Assets
Diesel Scope 1 Scope 3 Upstream Leased Assets
Fuel Oil Scope 1 Scope 3 Upstream Leased Assets
Heat Scope 2 Scope 3 Upstream Leased Assets
Heavy Oil Scope 1 Scope 3 Upstream Leased Assets
Kerosene Scope 1 Scope 3 Upstream Leased Assets
Light Oil Scope 1 Scope 3 Upstream Leased Assets
Liquid Natural Gas Scope 1 Scope 3 Upstream Leased Assets
Natural Gas Scope 1 Scope 3 Upstream Leased Assets
Propane Scope 1 Scope 3 Upstream Leased Assets
Refrigerant Scope 1 Scope 3 Upstream Leased Assets
Steam Scope 2 Scope 3 Upstream Leased Assets

For information about converting the values from one unit of measure to another compatible unit of measure, see Conversion Factors.

Here are the calculated fields:

  • Fuel Consumption (kWh) (FuelConsumptionInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Fuel Consumption (FuelConsumption)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)

      Fuel Type (FuelType)

      Calorific Value (CalorificValue)

      Calorific Value Unit (CalorificValueUnit)

    • Conversion constant

    Calculations

    If these fuels are measured in volume units:

    • City Gas
    • Diesel
    • Fuel Oil
    • Heavy Oil
    • Kerosene
    • Light Oil
    • Liquid Natural Gas (LNG)
    • Natural Gas
    • Propane
    • Biomass

    Then to convert the volume to energy units:

    Fuel Consumption (kWh) = Fuel Consumption (converted to m3) × OtherEmssnFctrSet.OtherEmssnFctrSetItem.Calorific Value (converted to kWh/m3) and Fuel Type = OtherEmssnFctrSet.OtherEmssnFctrSetItem.Fuel Type

  • Fuel Consumption (GJ) (FuelConsumptionInGigajoule)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Conversion constant

    Calculations

    Fuel Consumption (GJ) = Total Fuel Consumption (kWh)/277.7777777

  • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)

    Input Fields

    • Fuel Consumption (kWh) (FuelConsumptionInKwh)
    • Power Usage Effectiveness (PowerUsageEffectiveness)

    Calculations

    If Record Type = "Data Center", then Total Fuel Consumption (kWh) = Fuel Consumption (kWh) × Power Usage Effectiveness.

    else, for all other fuel types and record types, Total Fuel Consumption (kWh) = Fuel Consumption (kWh).

  • Occupied Floor Area (sqft) (OccupiedFloorAreaInSqft)

    Input Fields

    • Occupied Floor Area (OccupiedFloorArea)
    • Occupied Floor Area Unit (OccupiedFloorAreaUnit)
    • Conversion constant

    External Object Calculations

    If Occupied Floor Area Unit = "sqft", then Occupied Floor Area (sqft) = Occupied Floor Area.

    If Occupied Floor Area Unit = "m2", then Occupied Floor Area (sqft) = Occupied Floor Area × 10.76391042.

  • Scope 1 Emissions (tCO2e) (Scope1EmissionsInTco2e)

    Input Fields

    • Other Emissions Factors (OtherEmssnFctrId)
    • Supplemental Scope 1 Emissions (SuplScope1Emissions)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    • If Carbon Emission Scope Allocation = "Scope 1"

      or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation = "Scope 1" ( where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type )

      If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

      Note

    • If Fuel Type = "Electricity", then Scope 1 Emissions (tCO2e) = (Total Fuel Consumption (kWh)) × ElectricityEmssnFctrSet.CO2e Emissions Rate (tonnes/MWh)/1000 + Supplemental Scope 1 Emissions.
    • For any fuel other than refrigerants and electricity,

      If (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor = 0) then Scope 1 Emissions (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.CO2e Emissions Factor (tCO2e/MWh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 1 Emissions

      else if (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor != 0) then Scope 1 Emissions (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor (convert to Kg/Kwh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 1 Emissions.

    • If FuelType = "Refrigerant", then Scope 1 Emissions (tCO2e) = FuelConsumption (converted to Kgs) × RefrigerantEmssnFctr.Global Warming Potential/1000 + Supplemental Scope 1 Emission

    Default Value

    Scope 1 Emissions (tCO2e) = Supplemental Scope 1 Emissions

  • Scope 2 Location-Based Emission (tCO2e) (Scope2LocBasedEmssnInTco2e)

    Input Fields

    • Other Emissions Factors (OtherEmssnFctrId)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factors (ElectricityEmissionFactorsId)
    • Company-Owned Asset (IsCompanyOwnedAsset)
    • Supplemental Scope 2 Location-Based Emissions (SuplScope2LocationBasedEmssn)
    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    • If Carbon Emission Scope Allocation = "Scope 2"

      or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation = "Scope 2" (where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type)

      If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

      Note

    • If Fuel Type = "Electricity" then Scope 2 Location-Based Emission (tCO2e) =(Total Fuel Consumption (kWh) ) × Electricity Emissions Factor Set.Co2eEmissionRateInTmwh / 1000 + SuplScope2LocationBasedEmssn
    • For any fuel other than refrigerants and Electricity

      If (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor = 0) then Scope 2 Location-Based Emission (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.CO2e Emissions Factor (tCO2e/MWh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Location-Based Emissions

      else if (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor != 0) then Scope 2 Location-Based Emission (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor (convert to Kg/Kwh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Location-Based Emissions

    • If Fuel Type="Refrigerant" then Scope 2 Location-Based Emission (tCO2e) = Fuel Consumption (converted to Kgs) × RefrigerantEmssnFctr.Global Warming Potential/1000 + Supplemental Scope 2 Location-Based Emissions

    Default Value

    Scope 2 Location-Based Emission (tCO2e) = Supplemental Scope 2 Location-Based Emissions

  • Scope 2 Market-Based Emission (tCO2e) (Scope2MktBasedEmssnInTco2e)

    Input Fields

    • Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
    • Company-Owned Asset (IsCompanyOwnedAsset)
    • Electricity Emissions Factors (ElectricityEmissionFactorsId)
    • Emissions Factor Type (EmissionsFactorType)
    • Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
    • Emissions Factor Type (EmissionsFactorType)
    • Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
    • Supplemental Scope 2 Market-Based Emissions (SuplScope2MarketBasedEmssn)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Renewable Energy Type Override (RenewableEnergyType)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)
    • Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
    • Clean Energy Project (CleanEnergyProject)
    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    • If Fuel Type is not Electricity, Heat, Cooling, Steam OR Carbon Emission Scope Allocation != "Scope 2",

      then

      Scope 2 Market-Based Emission (tCO2e) = Supplemental Scope 2 Market-Based Emissions

    • If Renewable Energy Type Override ! = Empty,

      then Scope 2 Market-Based Emissions (tCO2e) = ((Total Fuel Consumption (kWh) - Allocated Renewable Energy Override (kWh) ) × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000))

      else if (ElectricityEmssnFctrSetId.Emissions Factor Type == LocationAndMarketBased or MarketBased) (ElectricityEmssnFctrSetId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000)) + totalEnergyAttrCreditDstrEmission + Supplemental Scope 2 Market-Based Emissions

    • If Renewable Energy Type Override == Empty (None),

      then Scope 2 Market-Based Emissions (tCO2e) =(Total Fuel Consumption (kWh) - Allocated Energy Attribute Credits (kWh)] ) × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000))) else if (MktBsdElectriEmssnFctrId.Emissions Factor Type == LocationAndMarketBased or MarketBased) (MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000)) + totalEnergyAttrCreditDstrEmission + Supplemental Scope 2 Market-Based Emissions

    Where totalEnergyAttrCreditDstrEmission = For each Energy Attribute Credit Distribution associated with this record if (EnergyAttrCreditDstr.EnergyAttrCertCredit.EnergyAttrCertPurchase.CleanEnergyProject.Electricity Emissions Factors !=NULL (EnergyAttrCreditDstr.Allocated Energy Attribute Credits (kWh) × EnergyAttrCreditDstr.EnergyAttrCertCredit.EnergyAttrCertPurchase.CleanEnergyProject.ElectrEmissionsFactorsId.Market-Based CO2e Emissions Rate (tonnes/MWh)))

    Default Value

    Scope 2 Market-Based Emission (tCO2e) = Supplemental Scope 2 Market-Based Emissions

  • Market-Based CO2 Emissions (kg) (MktBsdCo2EmssnInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
      • Fuel Type (FuelType)
      • CO2 Emissions Factor (Co2EmissionFactor)
      • CO2 Emissions Factor Unit (Co2EmissionFactorUnit)
    • Electricity Emissions Factors (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
    • Renewable Energy Type Override (RenewableEnergyType)
    • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)
    • Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
    • Clean Energy Project (CleanEnergyProject)
      • Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)

    Calculations

    • If Fuel Type is not Electricity, Heat, Cooling, Steam OR Scope Allocation is not Scope 2,

      then

      Market-Based CO2 Emissions (kg) = 0

    • If Renewable Energy Type Override ! = Empty,

      then Market-Based CO2 Emissions (kg) = (Total Fuel Consumption (kWh) - Allocated Renewable Energy Override (kWh)) × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Co2 Emissions Rate (tonnes/MWh) else if (ElectricityEmssnFctrSetId.Emissions Factor Type == LocationAndMarketBased or MarketBased) (ElectricityEmssnFctrSetId.Market-Based Co2 Emissions Rate (tonnes/MWh))) + totalEnergyAttrCreditDstrEmission

    • If Renewable Energy Type Override = = Empty, then Market-Based CO2 Emissions (kg) = (Total Fuel Consumption (kWh) - Allocated Renewable Energy Override (kWh)) × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Co2 Emissions Rate (tonnes/MWh) else if (ElectricityEmssnFctrSetId.Emissions Factor Type == LocationAndMarketBased or MarketBased) (ElectricityEmssnFctrSetId.Market-Based Co2 Emissions Rate (tonnes/MWh))) + totalEnergyAttrCreditDstrEmission

    Where totalEnergyAttrCreditDstrEmission = For each Energy Attribute Credit Distribution associated with this record if (EnergyAttrCreditDstr.EnergyAttrCertCredit.EnergyAttrCertPurchase.CleanEnergyProject.Electricity Emissions Factors !=NULL (EnergyAttrCreditDstr.Allocated Energy Attribute Credits (kWh) × EnergyAttrCreditDstr.EnergyAttrCertCredit.EnergyAttrCertPurchase.CleanEnergyProject.ElectrEmissionsFactorsId.Market-Based Co2 Emissions Rate (tonnes/MWh) * 1000)

  • Market-Based CH4 Emissions (kg) (MktBsdCh4EmssnInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
      • Fuel Type (FuelType)
      • CH4 Emissions Factor (Ch4EmissionFactor)
      • CH4 Emissions Factor Unit (Ch4EmissionFactorUnit)
    • Electricity Emission Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based CH4 Emissions Rate (tonnes/GWh) (MktBsdCh4EmssnRtInTgwh)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based CH4 Emissions Rate (tonnes/GWh) (MktBsdCh4EmssnRtInTgwh)
    • Renewable Energy Type Override (RenewableEnergyType)
    • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
      • Stationary Asset Energy Use (StnryAssetEnergyUseId)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)
    • Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
    • Clean Energy Project (CleanEnergyProject)
      • Electricity Emissions Factors (ElectrEmissionsFactorsId)

        Market-Based CH4 Emissions Rate (tonnes/GWh) (MktBsdCh4EmssnRtInTgwh)

    Calculations

    • If Fuel Type is not Electricity, Heat, Cooling, Steam OR Scope Allocation is not Scope 2,

      then

      Market-Based CH4 Emissions (kg) = 0

    • If (Renewable Energy Type Override!= Empty) { Market-Based CH4 Emissions (kg) = (Total Fuel Consumption (kWh) - Allocated Renewable Energy Override (kWh)) * (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Ch4 Emissions Rate (tonnes/GWh)/ 1000) else if (ElectricityEmssnFctrSetId.Emissions Factor Type == LocationAndMarketBased or MarketBased) (ElectricityEmssnFctrSetId.Market-Based Ch4 Emissions Rate (tonnes/GWh) / 1000)) + totalEnergyAttrCreditDstrEmission
    • If (Renewable Energy Type Override == Empty) { Market-Based CH4 Emissions (kg) = (Total Fuel Consumption (kWh) - Allocated Renewable Energy Override (kWh)) * (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Ch4 Emissions Rate (tonnes/GWh)/ 1000) else if (ElectricityEmssnFctrSetId.Emissions Factor Type == LocationAndMarketBased or MarketBased) (ElectricityEmssnFctrSetId.Market-Based Ch4 Emissions Rate (tonnes/GWh) / 1000)) + totalEnergyAttrCreditDstrEmission

    Where totalEnergyAttrCreditDstrEmission = For each Energy Attribute Credit Distribution associated with this record if (EnergyAttrCreditDstr.EnergyAttrCertCredit.EnergyAttrCertPurchase.CleanEnergyProject.Electricity Emissions Factors !=NULL (EnergyAttrCreditDstr.Allocated Energy Attribute Credits (kWh) × EnergyAttrCreditDstr.EnergyAttrCertCredit.EnergyAttrCertPurchase.CleanEnergyProject.ElectrEmissionsFactorsId.Market-Based Ch4 Emissions Rate (tonnes/GWh) * 1000)

  • Market-Based N2O Emissions (kg) (MktBsdN2oEmssnInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
      • Fuel Type (FuelType)
      • N2O Emissions Factor (N2oEmissionFactor)
      • N2O Emissions Factor Unit (N2oEmissionFactorUnit)
    • Electricity Emission Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based N2O Emissions Rate (tonnes/GWh) (MktBsdN2oEmssnRtInTgwh)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based N2O Emissions Rate (tonnes/GWh) (MktBsdN2oEmssnRtInTgwh)
    • Renewable Energy Type Override (RenewableEnergyType)
    • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
      • Stationary Asset Energy Use (StnryAssetEnergyUseId)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)

      Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)

    • Clean Energy Project (CleanEnergyProject)
      • Electricity Emissions Factors (ElectrEmissionsFactorsId)
      • Market-Based N2O Emissions Rate (tonnes/GWh) (MktBsdN2oEmssnRtInTgwh)

    Calculations

    • If Fuel Type is not Electricity, Heat, Cooling, Steam OR Scope Allocation is not Scope 2,

      then

      Market-Based N2O Emissions (kg) = 0

    • If (Renewable Energy Type Override!= Empty) { Market-Based N2O Emissions (kg) = (Total Fuel Consumption (kWh) TotalFuelConsumptionInKwh - Allocated Renewable Energy Override (kWh)) * (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based N2o Emissions Rate (tonnes/GWh)/ 1000) else if (ElectricityEmssnFctrSetId.Emissions Factor Type == LocationAndMarketBased or MarketBased) (ElectricityEmssnFctrSetId.Market-Based N2o Emissions Rate (tonnes/GWh) / 1000)) + totalEnergyAttrCreditDstrEmission
    • If (Renewable Energy Type Override == Empty) { Market-Based N2O Emissions (kg) = (Total Fuel Consumption (kWh) TotalFuelConsumptionInKwh - Allocated Renewable Energy Override (kWh)) * (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based N2o Emissions Rate (tonnes/GWh)/ 1000) else if (ElectricityEmssnFctrSetId.Emissions Factor Type == LocationAndMarketBased or MarketBased) (ElectricityEmssnFctrSetId.Market-Based N2o Emissions Rate (tonnes/GWh) / 1000)) + totalEnergyAttrCreditDstrEmission

    Where totalEnergyAttrCreditDstrEmission = For each Energy Attribute Credit Distribution associated with this record if (EnergyAttrCreditDstr.EnergyAttrCertCredit.EnergyAttrCertPurchase.CleanEnergyProject.Electricity Emissions Factors !=NULL (EnergyAttrCreditDstr.Allocated Energy Attribute Credits (kWh) × EnergyAttrCreditDstr.EnergyAttrCertCredit.EnergyAttrCertPurchase.CleanEnergyProject.ElectrEmissionsFactorsId.Market-Based N2o Emissions Rate (tonnes/GWh) * 1000)

  • Total Floor Area (sqft) (TotalFloorAreaInSqft)

    Input Fields

    • Total Floor Area (TotalFloorArea)
    • Total Floor Area Unit (TotalFloorAreaUnit)
    • Conversion constant

    External Object Calculations

    If Total Floor Area Unit = "sqft", then Total Floor Area (sqft) = Total Floor Area.

    If Total Floor Area Unit = "m2", then Total Floor Area (sqft) = Total Floor Area × 10.76391042.

  • Total Renewable Energy (kWh) (TotalRenewableEnergyInKwh)

    Input Fields

    • Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
    • Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)
    • Market-Based Electricity from Hydro (kWh) (MktBasedElectrFromHydroInKwh)
    • Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
    • Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)

    Calculations

    Total Renewable Energy (kWh) = Market-Based Electricity from Biomass (kWh) + Market-Based Electricity from Geothermal (kWh) + Market-Based Electricity from Hydro (kWh) + Market-Based Electricity from Solar (kWh) + Market-Based Electricity from Wind (kWh)

    Default Value

    0

  • Total Renewable Energy Excluding Hydro (kWh) (TotRnwlEnrgyExclHydroInKwh)

    Input Fields

    • Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
    • Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)
    • Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
    • Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)

    Calculations

    Total Renewable Energy Excluding Hydro (kWh) = Market-Based Electricity from Biomass (kWh) + Market-Based Electricity from Geothermal (kWh) + Market-Based Electricity from Solar (kWh) + Market-Based Electricity from Wind (kWh)

    Default Value

    0

  • Power Usage Effectiveness Monthly Range (IsPueMonthlyRange)

    Input Fields

    • Power Usage Effectiveness (PowerUsageEffectiveness)
    • Record Type

    Calculations

    If Record Type = "Data Center":

    If Power Usage Effectiveness >= 1 and Power Usage Effectiveness <= 2, then Power Usage Effectiveness Monthly Range = TRUE.

    If Power Usage Effectiveness <1 or Power Usage Effectiveness > 2, then Power Usage Effectiveness Monthly Range = FALSE.

  • Normalized Monthly Electricity Consumption (kWh) (NormalizedMoElectrCnsmpInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • End Date (EndDate)
    • Start Date (StartDate)

    Calculations

    Normalized Monthly Electricity Consumption (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × [30/(End Date – Start Date + 1)]

  • Location-Based Electricity from Biomass (kWh) (LocBasedElectrFrBiomassInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Biomass Mix Percentage (ElectricityEmssnFctrSet.LocationBasedBiomassMixPct)

    Calculations

    Location-Based Electricity from Biomass (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Biomass Mix Percentage/100

  • Location-Based Electricity from Coal (kWh) (LocBasedElectrFrCoalInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Coal Mix Percentage (ElectricityEmssnFctrSet.LocationBasedCoalMixPct)

    Calculations

    Location-Based Electricity from Coal (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Coal Mix Percentage/100

  • Location-Based Electricity from Gas (kWh) (LocBasedElectrFrGasInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Gas Mix Percentage (ElectricityEmssnFctrSet.LocationBasedGasMixPct)

    Calculations

    Location-Based Electricity from Gas (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Gas Mix Percentage/100

  • Location-Based Electricity from Hydro (kWh) (LocBasedElectrFrHydroInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Hydro Mix Percentage (ElectricityEmssnFctrSet.LocationBasedHydroMixPct)

    Calculations

    Location-Based Electricity from Hydro (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Hydro Mix Percentage/100

  • Location-Based Electricity from Nuclear (kWh) (LocBasedElectrFrNuclearInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Nuclear Mix Percentage (ElectricityEmssnFctrSet.LocationBasedNuclearMixPct)

    Calculations

    Location-Based Electricity from Nuclear (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × Electricity Emissions Factor Set.Location-Based Nuclear Mix Percentage/100

  • Location-Based Electricity from Oil (kWh) (LocBasedElectrFrOilInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Oil Mix Percentage (ElectricityEmssnFctrSet.LocationBasedOilMixPct)

    Calculations

    Location-Based Electricity from Oil (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × ElectricityEmssnFctrSet.Location-Based Oil Mix Percentage/100

  • Location-Based Electricity from Other Fuel (kWh) (LocBasedElectrFrOthrFuelInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Other Fuel Mix Percentage (ElectricityEmssnFctrSet.LocationBasedOtherFuelMixPct)

    Calculations

    Location-Based Electricity from Other Fuel (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Other Fuel Mix Percentage/100

  • Location-Based Electricity from Solar (kWh) (LocBasedElectrFrSolarInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Solar Mix Percentage (ElectricityEmssnFctrSet.LocationBasedSolarMixPct)

    Calculations

    Location-Based Electricity from Solar (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Solar Mix Percentage/100

  • Location-Based Electricity from Wind (kWh) (LocBasedElectrFrWindInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Wind Mix Percentage (ElectricityEmssnFctrSet.LocationBasedWindMixPct)

    Calculations

    Location-Based Electricity from Wind (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Wind Mix Percentage/100

  • Location-Based Electricity from Non-Renewables (kWh) (LocBsdElectrFrNonRenewablesKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Location-Based Electricity from Biomass (kWh) (LocBasedElectrFrBiomassInKwh)
    • Location-Based Electricity from Hydro (kWh) (LocBasedElectrFromHydroInKwh)
    • Location-Based Electricity from Solar (kWh) (LocBasedElectrFromSolarInKwh)
    • Location-Based Electricity from Wind (kWh) (LocBasedElectrFromWindInKwh)
    • Location-Based Electricity from Geothermal (kWh) (LocBsdElectrFrGeothermalInKwh)

    Calculations

    Location-Based Electricity from Non-Renewable (kWh) = Total Fuel Consumption (kWh) – Location-Based Electricity from Biomass (kWh) – Location-Based Electricity from Hydro (kWh) – Location-Based Electricity from Solar (kWh) – Location-Based Electricity from Wind (kWh) – Location-Based Electricity from Geothermal (kWh)

  • Location-Based Electricity from Geothermal (kWh) (LocBsdElectrFrGeothermalInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Geothermal Mix Percentage (ElectricityEmssnFctrSet.LocBasedGeothermalMixPct)

    Calculations

    Location-Based Electricity from Geothermal (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × ElectricityEmssnFctrSet.Location-Based Geothermal Mix Percentage/100

  • Location-Based Electricity from Other Fossil Fuel (kWh) (LocBsdElectrOthrFossilFuelKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Other Fossil Fuel Mix Percentage (ElectricityEmssnFctrSet.LocBasedOtherFossilFuelMixPct)

    Calculations

    Location-Based Electricity from Other Fossil Fuel (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × ElectricityEmssnFctrSet.Location-Based Other Fossil Fuel Mix Percentage/100

  • Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Allocated Energy Attribute Credits from Biomass (kWh) (AllocEnrgyAttrCrBiomass)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Biomass Mix Percentage (MarketBasedBiomassMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Biomass Mix Percentage (MarketBasedBiomassMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
      • Stationary Asset Energy Use (StnryAssetEnergyUseId)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)
    • Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Biomass (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctr.Market-Based Biomass Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Biomass Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Biomass (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctr.Market-Based Biomass Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Biomass Mix Percentage))

      else 0

  • Market-Based Electricity from Coal (kWh) (MktBasedElectrFromCoalInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Coal Mix Percentage (MarketBasedCoalMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Coal Mix Percentage (MarketBasedCoalMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Coal (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Coal Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Coal Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Coal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Coal Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Coal Mix Percentage))

      else 0

  • Market-Based Electricity from Gas (kWh) (MktBasedElectrFromGasInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Gas Mix Percentage (MarketBasedGasMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Gas Mix Percentage (MarketBasedGasMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
      • Stationary Asset Energy Use (StnryAssetEnergyUseId)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)
    • Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Gas (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Gas Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Gas Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object,

      if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Gas (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Gas Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Gas Mix Percentage))

      else 0

  • Market-Based Electricity from Hydro (kWh) (MktBasedElectrFromHydroInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Hydroelectric Mix Percentage (MarketBasedHydroMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Hydroelectric Mix Percentage (MarketBasedHydroelectricMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Hydro (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Hydro Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Hydro Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Hydro (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Hydro Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Hydro Mix Percentage))

      else 0

  • Market-Based Electricity from Nuclear (kWh) (MktBasedElectrFrNuclearInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Nuclear Mix Percentage (MarketBasedNuclearMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Nuclear Mix Percentage (MarketBasedNuclearMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Nuclear (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Nuclear Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Nuclear Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Nuclear (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Nuclear Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Nuclear Mix Percentage))

      else 0

  • Market-Based Electricity from Oil (kWh) (MktBasedElectrFromOilInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Oil Mix Percentage (MarketBasedOilMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Oil Mix Percentage (MarketBasedOilMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Oil (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Oil Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Oil Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Oil (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Oil Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Oil Mix Percentage))

      else 0

  • Market-Based Electricity from Other Fuel (kWh) (MktBasedEnrgyFromOthrFuelInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Other Fuel Mix Percentage (MarketBasedOtherFuelMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Other Fuel Mix Percentage (MarketBasedOtherFuelMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Other Fuel (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fuel Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Other Fuel Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Other Fuel (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fuel Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Other Fuel Mix Percentage))

      else 0

  • Market-Based Electricity from Solar (kWh) (MktBasedEnrgyFromSolarInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Allocated Energy Attribute Credits from Solar (kWh) (AllocEnrgyAttrCrSolar)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Solar Mix Percentage (MarketBasedSolarMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Solar Mix Percentage (MarketBasedSolarMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Solar (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Solar Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Solar Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Solar (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Solar Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Solar Mix Percentage))

      else 0

  • Market-Based Electricity from Wind (kWh) (MktBasedEnrgyFromWindInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Allocated Energy Attribute Credits from Wind (kWh) (AllocEnrgyAttrCrWind)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Wind Mix Percentage (MarketBasedWindMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Wind Mix Percentage (MarketBasedWindMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Wind (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Wind Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Wind Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Wind (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Wind Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Wind Mix Percentage))

      else 0

  • Market-Based Electricity from Non-Renewables (kWh) (MktBsdEnrgyFrNonRenewablesKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
    • Market-Based Electricity from Hydro (kWh) (MktBasedElectrFromHydroInKwh)
    • Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
    • Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)
    • Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)

    Calculations

    Market-Based Electricity from Non-Renewables (kWh) = Total Fuel Consumption (kWh) – Market-Based Electricity from Biomass (kWh) – Market-Based Electricity from Hydro (kWh) – Market-Based Electricity from Solar (kWh) – Market-Based Electricity from Wind (kWh) – Market-Based Electricity from Geothermal (kWh)

  • Market-Based Electricity from Geothermal (kWh) (MktBsdEnrgyFromGeothermalInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Allocated Energy Attribute Credits from Geothermal (kWh) (AllocEnrgyAttrCrGeothermal)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmssnFctrSet)
      • Market-Based Geothermal Mix Percentage (MktBasedGeothermalMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type = "Geothermal", then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100 + Allocated Renewable Energy (kWh)
    • If Renewable Energy Type ! = "Geothermal" && !Empty, then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100
    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type == Empty (None), then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Energy Attribute Credits (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100 + Allocated Energy Attribute Credits from Geothermal (kWh)
    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Geothermal Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Geothermal Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Geothermal Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Geothermal Mix Percentage))

      else 0

  • Market-Based Electricity from Other Fossil Fuel (kWh) (MktBsdElectrOthrFossilFuelKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Allocated Energy Attribute Credits from Geothermal (kWh) (AllocEnrgyAttrCrGeothermal)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Other Fossil Fuel Mix Percentage (MktBasedOtherFossilFuelMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Other Fossil Fuel Mix Percentage (MktBasedOtherFossilFuelMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Other Fossil Fuel (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fossil Fuel Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Other Fossil Fuel Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Other Fossil Fuel (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fossil Fuel Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Other Fossil Fuel Mix Percentage))

      else 0

  • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)

    Input Fields

    • Allocated Energy Attribute Credits from Biomass (kWh) (AllocEnrgyAttrCrBiomassNumber)
    • Allocated Energy Attribute Credits from Geothermal (kWh) (AllocEnrgyAttrCrGeothermalNumber)
    • Allocated Energy Attribute Credits from Solar (kWh) (AllocEnrgyAttrCrSolarNumber)
    • Allocated Energy Attribute Credits from Wind (kWh) (AllocEnrgyAttrCrWind)

    Calculations

    Allocated Energy Attribute Credits (kWh) = Allocated Energy Attribute Credits from Biomass (kWh) + Allocated Energy Attribute Credits from Geothermal (kWh) + Allocated Energy Attribute Credits from Wind (kWh) + Allocated Energy Attribute Credits from Solar (kWh)

  • Scope 3 Downstream Emissions (tCO2e) (Scope3DnstrmEmissionsIntCO2e)

    Input Fields

    • Other Emissions Factors (OtherEmissionFactors)
    • Supplemental Scope 3 Downstream Emissions (SuplScope3DnstrmEmissions)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    If Carbon Emission Scope Allocation value is one of these values

    • Scope 3 Downstream
    • Scope 3 Downstream Leased Assets
    • Scope 3 End-of-Life Treatment of Sold Products
    • Scope 3 Franchises
    • Scope 3 Investments
    • Scope 3 Processing of Sold Products
    • Scope 3 Use of Sold Products

    or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation value is one of these values

    • Scope 3 Downstream
    • Scope 3 Downstream Leased Assets
    • Scope 3 End-of-Life Treatment of Sold Products
    • Scope 3 Franchises
    • Scope 3 Investments
    • Scope 3 Processing of Sold Products
    • Scope 3 Use of Sold Products

    (where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type)

    If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

    Note

    Then see the calculations for Scope 1 Emissions (tCO2e)

    Default Value

    Scope3DnstrmEmissionsIntCO2e = SuplScope3DnstrmEmissions

  • Scope 3 Upstream Emissions (tCO2e) (Scope3UpstrmEmissionsInTco2e)

    Input Fields

    • Other Emissions Factors (OtherEmissionFactors)
    • Supplemental Scope 3 Upstream Emissions (SuplScope3UpstrmEmissions)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    If Carbon Emission Scope Allocation value is one of these values

    • Scope 3 Upstream
    • Scope 3 Capital Goods
    • Scope 3 Employee Commuting
    • Scope 3 Fuel and Energy-Related Activities
    • Scope 3 Purchased Goods and Services
    • Scope 3 Upstream Leased Assets
    • Scope 3 Waste Generated In Operations

    or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation value is one of these values

    • Scope 3 Upstream
    • Scope 3 Capital Goods
    • Scope 3 Employee Commuting
    • Scope 3 Fuel and Energy-Related Activities
    • Scope 3 Purchased Goods and Services
    • Scope 3 Upstream Leased Assets
    • Scope 3 Waste Generated In Operations

    (where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type)

    If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

    Note

    Then see the calculations for Scope 1 Emissions (tCO2e)

    Default Value

    Scope 3 Upstream Emissions (tCO2e) = Supplemental Scope 3 Upstream Emissions

  • Scope 3 GHG Category (Scope3GhgCategory)

    Input Fields

    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    If Carbon Emission Scope Allocation value is one of these values

    • Scope 3 Purchased Goods and Services
    • Scope 3 Capital Goods
    • Scope 3 Processing of Sold Products
    • Scope 3 Upstream Leased Assets
    • Scope 3 Fuel and Energy-Related Activities
    • Scope 3 Employee Commuting
    • Scope 3 End-of-Life Treatment of Sold Products
    • Scope 3 Waste Generated In Operations
    • Scope 3 Use of Sold Products
    • Scope 3 Downstream Leased Assets
    • Scope 3 Investments
    • Scope 3 Franchises

    then

    Scope 3 GHG Category = CrbnEmssnScopeAllocVal.FuelTypeAllocation

    or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation value is one of these values

    • Scope 3 Purchased Goods and Services
    • Scope 3 Capital Goods
    • Scope 3 Processing of Sold Products
    • Scope 3 Upstream Leased Assets
    • Scope 3 Fuel and Energy-Related Activities
    • Scope 3 Employee Commuting
    • Scope 3 End-of-Life Treatment of Sold Products
    • Scope 3 Waste Generated In Operations
    • Scope 3 Use of Sold Products
    • Scope 3 Downstream Leased Assets
    • Scope 3 Investments
    • Scope 3 Franchises

    (where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type)

    then

    Scope 3 GHG Category = StnryAssetEnvrSrc.CrbnEmssnScopeAllocId.FuelTypeAllocation

    If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

    Note

    else

    Scope 3 GHG Category = null

  • CH4 Emissions (kg) (Ch4EmissionsInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)

      Fuel Type (FuelType)

      CH4 Emissions Factor (Ch4EmissionFactor)

    • Electricity Emission Factor Set (ElectricityEmssnFctrSet)

      CH4 Emissions Rate (tonnes/GWh) (Ch4EmissionRateInTgwh)

    Calculations

    If Fuel Type = "Electricity"

    • CH4 Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.CH4 Emissions Rate (tonnes/GWh) × 1000/1000000.0

    Default = 0

    For any fuel other than refrigerants and electricity

    • If CH4 Emissions Factor is in energy units

      CH4 Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.CH4 Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.CH4 Emissions Factor is converted to Kg/Kwh

    • else CH4 Emissions (kg) = 0
  • CO2 Emissions (kg) (Co2EmissionsInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)

      Fuel Type (FuelType)

      CO2 Emissions Factor (Co2EmissionFactor)

    • Electricity Emission Factor Set (ElectricityEmssnFctrSet)

      CO2 Emissions Rate (tonnes/MWh) (Co2EmissionRateInTmwh)

    Calculations

    If Fuel Type = "Electricity"

    • CO2 Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.CO2 Emissions Rate (tonnes/MWh) × 1000/1000.0

    Default = 0

    For any fuel other than refrigerants and electricity

    • If CO2 Emissions Factor is in energy units

      CO2 Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.CO2 Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.CO2 Emissions Factor is converted to Kg/Kwh

    • else CO2 Emissions (kg) = 0
  • N2O Emissions (kg) (N2oEmissionsInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)

      Fuel Type (FelType)

      N2O Emissions Factor (N2oEmissionFactor)

    • Electricity Emission Factor Set (ElectricityEmssnFctrSet)

      N2O Emissions Rate (tonnes/GWh) (N2oEmissionRateInTgwh)

    Calculations

    If Fuel Type = "Electricity"

    • N2O Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.N2O Emissions Rate (tonnes/GWh) × 1000/1000000.0

    Default = 0

    For any fuel other than refrigerants and electricity

    • If N2O Emissions Factor is in energy units

      N2O Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.N2O Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.N2O Emissions Factor is converted to Kg/Kwh

    • else N2O Emissions (kg) = 0
  • Fuel Consumption

    Inputs

    • Occupied Floor Area (OccupiedFloorArea)
    • Occupied Floor Area Unit (OccupiedFloorAreaUnit)
    • Other Emission Factors (OtherEmissionFactors)
    • Refrigerant Leakage Rate (kg/sqft) (RefrigerantLeakageRtInKgSqft)

    Calculations

    If (Fuel Type = "Refrigerant") and Fuel Consumption is NULL

    then

    Fuel Consumption = Occupied Floor Area (converted to sqft) × OtherEmissionFactors.Refrigerant Leakage Rate (kg/sqft)

  • Scope 3 CH4 Emissions from Fuel and Energy-Related Activity (Kg) (Scp3Ch4EmssnFuelEnrgy)

    Inputs

    • Fuel Type (FuelType)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Other Lifecycle Emission Factor Set (OthrLifecyclEmssnFctrSetId)
      • Other Lifecycle Emission Factor Set Item (OthrLifecyclEmssnFctrSetItem)
        • Well-To-Tank CH4 Emissions Factor (Well2TkCh4EmssnFctr)
        • Well-To-Tank CH4 Emissions Factor Unit (Well2TkCh4EmssnFctrUnit)
        • Transmission and Distribution CH4 Emissions Factor (TrnsmDstrCh4EmssnFctr)
        • Transmission and Distribution CH4 Emissions Factor Unit (TrnsmDstrCh4EmssnFctrUnit)
        • Well-To-Tank Transmission and Distribution CH4 Emissions Factor (Well2TkTrnsmCh4Emssn)
        • Well-To-Tank Transmission and Distribution CH4 Emissions Factor Unit (Well2TkTrnsmCh4EmssnUnit)

    Calculations

    If Fuel Type = "Refrigerant" or Fuel Type = "Electricity", then Scope 3 CH4 Emissions from Fuel and Energy-Related Activity (Kg) = 0.

    For any fuel other than refrigerants and electricity, Scope 3 CH4 Emissions from Fuel and Energy-Related Activity (Kg) = Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank CH4 Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank CH4 Emissions Factor Unit) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution CH4 Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution CH4 Emissions Factor Unit ) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution CH4 Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution CH4 Emissions Factor Unit)

  • Scope 3 CO2 Emissions from Fuel and Energy-Related Activity (Kg) (Scp3Co2EmssnFuelEnrgy)

    Inputs

    • Fuel Type (FuelType)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Other Lifecycle Emission Factor Set (OthrLifecyclEmssnFctrSetId)
      • Other Lifecycle Emission Factor Set Item (OthrLifecyclEmssnFctrSetItem)
        • Well-To-Tank CO2 Emissions Factor (Well2TkCo2EmssnFctr)
        • Well-To-Tank CO2 Emissions Factor Unit (Well2TkCo2EmssnFctrUnit)
        • Transmission and Distribution CO2 Emissions Factor (TrnsmDstrCo2EmssnFctr)
        • Transmission and Distribution CO2 Emissions Factor Unit (TrnsmDstrCo2EmssnFctrUnit)
        • Well-To-Tank Transmission and Distribution CO2 Emissions Factor (Well2TkTrnsmCo2Emssn)
        • Well-To-Tank Transmission and Distribution CO2 Emissions Factor Unit (Well2TkTrnsmCo2EmssnUnit)

    Calculations

    If FuelType = "Refrigerant" or FuelType = "Electricity", then Scope 3 CO2 Emissions from Fuel and Energy-Related Activity (Kg) = 0

    For any fuel other than refrigerants and electricity, Scope 3 CO2 Emissions from Fuel and Energy-Related Activity (Kg) = Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank CO2 Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank CO2 Emissions Factor Unit ) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution CO2 Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution CO2 Emissions Factor Unit) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution CO2 Emissions × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution CO2 Emissions Factor Unit)

  • Scope 3 N2O Emissions from Fuel and Energy-Related Activity (Kg) (Scp3N2oEmssnFuelEnrgy)

    Inputs

    • Fuel Type (FuelType)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Other Lifecycle Emission Factor Set (OthrLifecyclEmssnFctrSetId)
      • Other Lifecycle Emission Factor Set Item (OthrLifecyclEmssnFctrSetItem)
        • Well-To-Tank N2O Emissions Factor (Well2TkN2oEmssnFctr)
        • Well-To-Tank N2O Emissions Factor Unit (Well2TkN2oEmssnFctrUnit)
        • Transmission and Distribution N2O Emissions Factor (TrnsmDstrN2oEmssnFctr)
        • Transmission and Distribution N2O Emissions Factor Unit (TrnsmDstrN2oEmssnFctrUnit)
        • Well-To-Tank Transmission and Distribution N2O Emissions Factor (Well2TkTrnsmN2oEmssn)
        • Well-To-Tank Transmission and Distribution N2O Emissions Factor Unit (Well2TkTrnsmN2oEmssnUnit)

    Calculations

    If FuelType = "Refrigerant" or FuelType = "Electricity", then Scope 3 N2O Emissions from Fuel and Energy-Related Activity (Kg) = 0

    For any fuel other than refrigerants and electricity, Scope 3 N2O Emissions from Fuel and Energy-Related Activity (Kg) = Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank N2O Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank N2O Emissions Factor Unit) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution N2O Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution N2O Emissions Factor Unit) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution N2O Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution N2O Emissions Factor Unit)

  • Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e) (Scp3EmssnFuelEnrgy)

    Inputs

    • Fuel Type (FuelType)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Lifecycle Emission Factor Set (ElectrLifecyclEmssnFctrSet)
      • Fuel-Cycle Factor (FuelCycleFactor)
      • Fuel-Cycle Factor Unit (FuelCycleFactorUnit)
      • Lifecycle Transmission and Distribution Factor (LifecyclTrnsmDstrFctr)
      • Lifecycle Transmission and Distribution Factor Unit (LifecyclTrnsmDstrFctrUnit)
    • Other Lifecycle Emission Factor Set (OthrLifecyclEmssnFctrSetId)
      • Other Lifecycle Emission Factor Set Item (OthrLifecyclEmssnFctrSetItem)
        • Well-To-Tank Supplied CO2e Emissions Factor (Well2TkSuplCo2eEmssn)
        • Well-To-Tank Supplied CO2e Emissions Factor Unit (Well2TkSuplCo2eEmssnUnit)
        • Well-To-Tank CO2e Emissions Factor (tCO2e/MWh) (Well2TkCo2eEmssnFctrMwh)
        • Transmission and Distribution Supplied CO2e Emissions Factor (TrnsmDstrSuplCo2eEmssn)
        • Transmission and Distribution Supplied CO2e Emissions Factor Unit (TrnsmDstrSuplCo2eEmssnUnit)
        • Transmission and Distribution CO2e Emissions Factor (tCO2e/MWh) (TrnsmDstrCo2eEmssnMwh)
        • Well-To-Tank Transmission and Distribution CO2e Emissions Factor (tCO2e/MWh) (Well2TkTrnsmCo2eEmssnMwh)
        • Well-To-Tank Transmission and Distribution Supplied CO2e Emissions Factor (Well2TkTrnsmSuplCo2e)
        • Well-To-Tank Transmission and Distribution Supplied CO2e Emissions Factor Unit (Well2TkTrnsmSuplCo2eUnit)
        • Well-To-Tank Transmission and Distribution CO2e Emissions Factor (tCO2e/MWh) (Well2TkTrnsmCo2eEmssnMwh)

    Calculations

    If Fuel Type = "Refrigerant", then Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e) = 0

    If Fuel Type = "Electricity", then Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e) = (Total Fuel Consumption (kWh) × ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor Unit)) / 1000 + (Total Fuel Consumption (kWh) × ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor Unit)) / 1000

    For any fuel other than refrigerants and electricity, Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e) = Well2Tk Component + TrnsmDstr Component + Well2TkTrnsm Component, where:

    Well2Tk Component: If OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Supplied CO2e Emissions Factor = 0 or NULL, then (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank CO2e Emissions Factor (tCO2e/MWh)) / 1000, else (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Supplied CO2e Emissions Factor × (conversion factor for tonnes/MWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Supplied CO2e Emissions Factor Unit )) / 1000

    TrnsmDstr Component: If OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution Supplied CO2e Emissions Factor = 0 or NULL, then (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution CO2e Emissions Factor (tCO2e/MWh)) / 1000, else (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution Supplied CO2e Emissions Factor × (conversion factor for tonnes/MWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution Supplied CO2e Emissions Factor Unit)) / 1000

    Well2TkTrnsm Component: If OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution Supplied CO2e Emissions Factor = 0 or NULL, then (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution CO2e Emissions Factor (tCO2e/MWh)) / 1000, else (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution Supplied CO2e Emissions Factor × (conversion factor for tonnes/MWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution Supplied CO2e Emissions Factor Unit)) / 1000

  • Scope 3 Market-Based Emissions from Fuel and Energy-Related Activity (tCO2e) (Scp3MktEmssnFuelEnrgy)

    Inputs

    • Fuel Type (FuelType)
    • Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e) (Scp3EmssnFuelEnrgy)
    • Renewable Energy Type Override (RenewableEnergyType)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
    • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
    • Electricity Lifecycle Emission Factor Set (ElectrLifecyclEmssnFctrSet)
      • Fuel-Cycle Factor (FuelCycleFactor)
      • Fuel-Cycle Factor Unit (FuelCycleFactorUnit)
      • Lifecycle Transmission and Distribution Factor (LifecyclTrnsmDstrFctr)
      • Lifecycle Transmission and Distribution Factor Unit (LifecyclTrnsmDstrFctrUnit)

    Calculations

    For Fuel Type != "Electricity", Scope 3 Market-Based Emissions from Fuel and Energy-Related Activity (tCO2e) value would be same as Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e)

    For Fuel Type = "Electricity" - If Renewable Energy Type Override is not empty, then Scope 3 Market-Based Emissions from Fuel and Energy-Related Activity (tCO2e) = ((Total Fuel Consumption (kWh) - Allocated Renewable Energy Override (kWh)) × ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor Unit)) / 1000 + (Total Fuel Consumption (kWh) × ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor Unit )) / 1000, else Scope 3 Market-Based Emissions from Fuel and Energy-Related Activity (tCO2e) = ((Total Fuel Consumption (kWh) - Allocated Energy Attribute Credits (kWh)) × ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor Unit)) / 1000 + (Total Fuel Consumption (kWh) × ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor Unit )) / 1000