Newer Version Available
Stationary Asset Energy Use
| Available in: Lightning Experience and the Salesforce mobile app |
| Available in: Enterprise, Developer, Performance, and Unlimited Editions |
| Permission Set Needed | |
|---|---|
| To enter and modify data: | Net Zero Cloud Manager |
| Fuel Units | Electricity | Cooling | Diesel | Fuel Oil/Heavy Oil | Heat | Natural Gas | Liquid Natural Gas (LNG) | Propane | Steam | Light Oil | Kerosene | City Gas | Refrigerant |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| kWh | X | X | X | X | X | X | X | X | X | X | X | X | |
| GWh | X | X | X | X | X | X | X | X | X | X | X | X | |
| MWh | X | X | X | X | X | X | X | X | X | X | X | X | |
| GJ | X | X | X | X | X | X | X | X | X | X | X | X | |
| MJ | X | X | X | X | X | X | X | X | X | X | X | X | |
| kcal | X | X | X | X | X | X | X | X | X | X | X | X | |
| MMBtu | X | X | X | X | X | X | X | X | X | X | X | X | |
| Therm | X | X | X | X | X | X | X | X | X | X | X | X | |
| Kg | X | ||||||||||||
| lbs | X | ||||||||||||
| Tonnes | X | ||||||||||||
| Short Tons | X | ||||||||||||
| Long Tons | X | ||||||||||||
| US Gallon | X | X | X | X | X | X | X | X | |||||
| UK Gallon | X | X | X | X | X | X | X | X | |||||
| Liter | X | X | X | X | X | X | X | X | |||||
| Kiloliters | X | X | X | X | X | X | X | X | |||||
| m3 | X | X | X | X | X | X | X | X | |||||
| 1000 m3 | X | X | X | X | X | X | X | X | |||||
| ccf | X | X | X | X | X | X | X | X |
Allocate the default scope for the fuel. Depending on the scope, the relevant fields are populated and the other fields default to 0:
- Scope 1 Emissions (tCO2e).
- Scope 2 Location-Based Emissions (tCO2e) and Scope 2 Market-Based Emissions (tCO2e). Scope 2 means both these fields are populated.
- Scope 3 Downstream Emissions (tCO2e).
- Scope 3 Upstream Emissions (tCO2e).
If you have not associated a scope allocation, then use the default scope allocations.
| Fuel | Asset Owned | Asset Not Owned |
|---|---|---|
| Electricity | Scope 2 | Scope 2 |
| City Gas | Scope 1 | Scope 2 |
| Cooling | Scope 2 | Scope 2 |
| Diesel | Scope 1 | Scope 2 |
| Fuel Oil | Scope 1 | Scope 2 |
| Heat | Scope 2 | Scope 2 |
| Heavy Oil | Scope 1 | Scope 2 |
| Kerosene | Scope 1 | Scope 2 |
| Light Oil | Scope 1 | Scope 2 |
| Liquid Natural Gas (LNG) | Scope 1 | Scope 2 |
| Natural Gas | Scope 1 | Scope 2 |
| Propane | Scope 1 | Scope 2 |
| Refrigerant | Scope 1 | Scope 2 |
| Steam | Scope 2 | Scope 2 |
| IT Electricity | Scope 2 | Scope 2 |
Here are the calculated fields:
-
Fuel Consumption (kWh) (FuelConsumptionInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
- Fuel Consumption (FuelConsumption)
-
Other Emissions Factor Set (OtherEmssnFctrSet)
-
Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
Fuel Type (FuelType)
Calorific Value (CalorificValue)
Calorific Value Unit (CalorificValueUnit)
-
Conversion constant
Calculations
If these fuels are measured in volume units:
- City Gas
- Diesel
- Fuel Oil
- Heavy Oil
- Kerosene
- Light Oil
- Liquid Natural Gas (LNG)
- Natural Gas
- Propane
- Biomass
Then to convert the volume to energy units:
Fuel Consumption (kWh) = Fuel Consumption (converted to m3) × OtherEmssnFctrSet.OtherEmssnFctrSetItem.Calorific Value (converted to kWh/m3) and Fuel Type = OtherEmssnFctrSet.OtherEmssnFctrSetItem.Fuel Type
-
-
Fuel Consumption (GJ) (FuelConsumptionInGigajoule)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Conversion constant
Calculations
Fuel Consumption (GJ) = Total Fuel Consumption (kWh)/277.7777777
-
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
Input Fields
-
Fuel Consumption (kWh) (FuelConsumptionInKwh)
-
Power Usage Effectiveness (PowerUsageEffectiveness)
Calculations
If Record Type = “Data Center”, then Total Fuel Consumption (kWh) = Fuel Consumption (kWh) × Power Usage Effectiveness.
Else, for all other fuel types and record types, Total Fuel Consumption (kWh) = Fuel Consumption (kWh).
-
-
Occupied Floor Area (sqft) (OccupiedFloorAreaInSqft)
Input Fields
-
Occupied Floor Area (OccupiedFloorArea)
-
Occupied Floor Area Unit (OccupiedFloorAreaUnit)
-
Conversion constant
External Object Calculations
If Occupied Floor Area Unit = “sqft”, then Occupied Floor Area (sqft) = Occupied Floor Area.
If Occupied Floor Area Unit = “m2”, then Occupied Floor Area (sqft) = Occupied Floor Area × 10.76391042.
-
-
Refrigerant Emissions (tCO2e) (RefrigerantEmissionsInTco2e)
Input Fields
-
Final Energy Consumption (Final Energy Consumption ) = Data Center or Occupied Floor Area (sqft) Occupied Floor Area (sqft) = Commercial Building
-
Record type of BPO
-
Refrigerant Emissions Factor.Global Warming Potential (kgCO2e/kg) (RefrigerantEmssnFctr.GlblWarmingPotInKgCo2eKg)
Calculations
Refrigerant Emissions (tCO2e) = Final Energy Consumption (converted to kg) × RefrigerantEmssnFctr.Global Warming Potential
Default Value
0
-
-
Scope 1 Emissions (tCO2e) (Scope1EmissionsInTco2e)
Input Fields
-
Other Emissions Factors (OtherEmissionFactors)
-
Supplemental Scope 1 Emissions (SuplScope1Emissions)
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Stationary Asset Environmental Source (StnryAssetEnvrSrc)
Calculations
If the scope allocation for a fuel is scope 1, then
StnryAssetEnvrSrc.Carbon Emissions Scope Allocation.Fuel Type Allocation = “Scope 1” where StnryAssetEnvrSrc.CrbnEmssnScopeAlloc.FuelType = FuelType.
If Fuel Type = “Electricity”, then Scope 1 Emissions (tCO2e) = (Total Fuel Consumption (kWh)) × ElectricityEmssnFctrSet.CO2e Emissions Rate (tonnes/MWh)/1000 + Supplemental Scope 1 Emissions.
For any fuel other than refrigerants and electricity,
If SuppliedEmssnFactorInTco2eMwh = 0, then Scope 1 Emissions (tCO2e) = Total Fuel Consumption (kWh) × OtherEmissionFactors.Other Emissions Factor Set Item.CO2e Emissions Factor (tCO2e/MWh) (FuelType = OtherEmissionFactors.Other Emissions Factor Set Item.Fuel Type)/1000 + Supplemental Scope 1 Emissions.
Else, if SuppliedEmssnFactorInTco2eMwh ! = 0, then Scope 1 Emissions (tCO2e) = Total Fuel Consumption (kWh) × OtherEmissionFactors.Other Emissions Factor Set Item.Supplied Emissions Factor (tCO2e/MWh) (Fuel Type = OtherEmissionFactors.Fuel Type)/1000 + Supplemental Scope 1 Emissions.
If FuelType = “Refrigerant”, then Scope 1 Emissions (tCO2e) = FuelConsumption (converted to Kgs) × RefrigerantEmssnFctr.Global Warming Potential + Supplemental Scope 1 Emission
Default Value
Scope 1 Emissions (tCO2e) = Supplemental Scope 1 Emissions
-
-
Scope 2 Location-Based Emission (tCO2e) (Scope2LocBasedEmssnInTco2e)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factors (ElectricityEmissionFactors)
-
Company-Owned Asset (IsCompanyOwnedAsset)
-
Supplemental Scope 2 Location-Based Emissions (SuplScope2LocationBasedEmssn)
Calculations
StnryAssetEnvrSrc.Carbon Emission Scope Allocation Value.Fuel Type Allocation = “Scope 2” ( where StnryAssetEnvrSrc.Carbon Emission Scope Allocation Value.Fuel Type = Fuel Type )- If Fuel Type = “Electricity”
- For any fuel other than refrigerants & Electricity
else if (Supplied Emissions Factor (tCO2e/MWh) != 0) then Scope 2 Location-Based Emission (tCO2e) = Total Fuel Consumption (kWh) × OtherEmissionFactors.Other Emissions Factor Set Item.Supplied Emissions Factor (tCO2e/MWh) (Fuel Type =Other Emissions Factor Set.Fuel Type) / 1000 + Supplemental Scope 2 Location-Based Emissions- If Fuel Type=“Refrigerant”,
Default Value
Scope 2 Location-Based Emission (tCO2e) = Supplemental Scope 2 Location-Based Emissions
-
-
Scope 2 Market-Based Emission (tCO2e) (Scope2MktBasedEmssnInTco2e)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factors (ElectricityEmissionFactors)
-
Company-Owned Asset (IsCompanyOwnedAsset)
-
Supplemental Scope 2 Market-Based Emissions (SuplScope2MarketBasedEmssn)
-
Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
Calculations
StnryAssetEnvrSrc.Carbon Emission Scope Allocation Value.Fuel Type Allocation = “Scope 2” ( where StnryAssetEnvrSrc.Carbon Emission Scope Allocation Value.Fuel Type = Fuel Type )- If Fuel Type = “Electricity”
- For any fuel other than refrigerants & Electricity
then Scope 2 Market-Based Emissions (tCO2e) = Total Fuel Consumption (kWh) × OtherEmissionFactors.Other Emissions Factor Set Item.CO2e Emissions Factor (tCO2e/MWh) (Fuel Type =OtherEmissionFactors.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Market-Based Emissions
else if (Supplied Emissions Factor (tCO2e/MWh) != 0) Scope 2 Market-Based Emissions (tCO2e) = Total Fuel Consumption (kWh) × OtherEmissionFactors.Other Emissions Factor Set Item.Supplied Emissions Factor (tCO2e/MWh) (Fuel Type =OtherEmissionFactors.Fuel Type) / 1000 + Supplemental Scope 2 Market-Based Emissions- If FuelType=“Refrigerant”,
Default Value
Scope 2 Market-Based Emission (tCO2e) = Supplemental Scope 2 Market-Based Emissions
-
-
Total Floor Area (sqft) (TotalFloorAreaInSqft)
Input Fields
-
Total Floor Area (TotalFloorArea)
-
Total Floor Area Unit (TotalFloorAreaUnit)
-
Conversion constant
External Object Calculations
If Total Floor Area Unit = “sqft”, then Total Floor Area (sqft) = Total Floor Area.
If Total Floor Area Unit = “m2”, then Total Floor Area (sqft) = Total Floor Area × 10.76391042.
-
-
Total Renewable Energy (kWh) (TotalRenewableEnergyInKwh)
Input Fields
-
Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
-
Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)
-
Market-Based Electricity from Hydro (kWh) (MktBasedElectrFromHydroInKwh)
-
Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
-
Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)
Calculations
Total Renewable Energy (kWh) = Market-Based Electricity from Biomass (kWh) + Market-Based Electricity from Geothermal (kWh) + Market-Based Electricity from Hydro (kWh) + Market-Based Electricity from Solar (kWh) + Market-Based Electricity from Wind (kWh)
Default Value
0
-
-
Total Renewable Energy Excluding Hydro (kWh) (TotRnwlEnrgyExclHydroInKwh)
Input Fields
-
Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
-
Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)
-
Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
-
Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)
Calculations
Total Renewable Energy Excluding Hydro (kWh) = Market-Based Electricity from Biomass (kWh) + Market-Based Electricity from Geothermal (kWh) + Market-Based Electricity from Solar (kWh) + Market-Based Electricity from Wind (kWh)
Default Value
0
-
-
Power Usage Effectiveness Monthly Range (IsPueMonthlyRange)
Input Fields
-
Power Usage Effectiveness (PowerUsageEffectiveness)
-
Record Type
Calculations
If Record Type = “Data Center”:
If Power Usage Effectiveness >= 1 and Power Usage Effectiveness <= 2, then Power Usage Effectiveness Monthly Range = TRUE.
If Power Usage Effectiveness <1 or Power Usage Effectiveness > 2, then Power Usage Effectiveness Monthly Range = FALSE.
-
-
Normalized Monthly Electricity Consumption (kWh) (NormalizedMoElectrCnsmpInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Fuel Type (FuelType)
-
End Date (EndDate)
-
Start Date (StartDate)
Calculations
Normalized Monthly Electricity Consumption (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) × [30/(End Date – Start Date + 1)]
-
-
Location-Based Electricity from Biomass (kWh) (LocBasedElectrFrBiomassInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Biomass Mix Percentage (ElectricityEmssnFctrSet.LocationBasedBiomassMixPct)
Calculations
Location-Based Electricity from Biomass (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) × ElectricityEmssnFctrSet.Location-Based Biomass Mix Percentage/100
-
-
Location-Based Electricity from Coal (kWh) (LocBasedElectrFrCoalInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Coal Mix Percentage (ElectricityEmssnFctrSet.LocationBasedCoalMixPct)
Calculations
Location-Based Electricity from Coal (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) × ElectricityEmssnFctrSet.Location-Based Coal Mix Percentage/100
-
-
Location-Based Electricity from Gas (kWh) (LocBasedElectrFrGasInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Gas Mix Percentage (ElectricityEmssnFctrSet.LocationBasedGasMixPct)
Calculations
Location-Based Electricity from Gas (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) × ElectricityEmssnFctrSet.Location-Based Gas Mix Percentage/100
-
-
Location-Based Electricity from Hydro (kWh) (LocBasedElectrFrHydroInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Hydro Mix Percentage (ElectricityEmssnFctrSet.LocationBasedHydroMixPct)
Calculations
Location-Based Electricity from Hydro (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) × ElectricityEmssnFctrSet.Location-Based Hydro Mix Percentage/100
-
-
Location-Based Electricity from Nuclear (kWh) (LocBasedElectrFrNuclearInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Nuclear Mix Percentage (ElectricityEmssnFctrSet.LocationBasedNuclearMixPct)
Calculations
Location-Based Electricity from Nuclear (kWh) = Total Fuel Consumption (kWh) (where FuelType = “Electricity”) × Electricity Emissions Factor Set.Location-Based Nuclear Mix Percentage/100
-
-
Location-Based Electricity from Oil (kWh) (LocBasedElectrFrOilInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Oil Mix Percentage (ElectricityEmssnFctrSet.LocationBasedOilMixPct)
Calculations
Location-Based Electricity from Oil (kWh) = Total Fuel Consumption (kWh) (where FuelType = “Electricity”) × ElectricityEmssnFctrSet.Location-Based Oil Mix Percentage/100
-
-
Location-Based Electricity from Other Fuel (kWh) (LocBasedElectrFrOthrFuelInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Other Fuel Mix Percentage (ElectricityEmssnFctrSet.LocationBasedOtherFuelMixPct)
Calculations
Location-Based Electricity from Other Fuel (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) × ElectricityEmssnFctrSet.Location-Based Other Fuel Mix Percentage/100
-
-
Location-Based Electricity from Solar (kWh) (LocBasedElectrFrSolarInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Solar Mix Percentage (ElectricityEmssnFctrSet.LocationBasedSolarMixPct)
Calculations
Location-Based Electricity from Solar (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) × ElectricityEmssnFctrSet.Location-Based Solar Mix Percentage/100
-
-
Location-Based Electricity from Wind (kWh) (LocBasedElectrFrWindInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Wind Mix Percentage (ElectricityEmssnFctrSet.LocationBasedWindMixPct)
Calculations
Location-Based Electricity from Wind (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) × ElectricityEmssnFctrSet.Location-Based Wind Mix Percentage/100
-
-
Location-Based Energy from Non-Renewable (LocBsdEnrgyFrNonRenewablesKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Location-Based Energy from Biomass (kWh) (LocBasedEnrgyFromBiomassInKwh)
-
Location-Based Energy from Hydro (kWh) (LocBasedEnrgyFromHydroInKwh)
-
Location-Based Energy from Solar (kWh) (LocBasedEnrgyFromSolarInKwh)
-
Location-Based Energy from Wind (kWh) (LocBasedEnrgyFromWindInKwh)
-
Location-Based Energy from Geothermal (LocBsdEnrgyFromGeothermalInKwh)
Calculations
Location-Based Energy from Non-Renewable = Total Fuel Consumption (kWh) – Location-Based Energy from Biomass (kWh) – Location-Based Energy from Hydro (kWh) – Location-Based Energy from Solar (kWh) – Location-Based Energy from Wind (kWh) – Location-Based Energy from Geothermal
-
-
Location-Based Electricity from Geothermal (kWh) (LocBsdEnrgyFromGeothermalInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Geothermal Mix Percentage (ElectricityEmssnFctrSet.LocBasedGeothermalMixPct)
Calculations
Location-Based Electricity from Geothermal (kWh) = Total Fuel Consumption (kWh) (where FuelType = “Electricity”) × ElectricityEmssnFctrSet.Location-Based Geothermal Mix Percentage/100
-
-
Location-Based Electricity from Geothermal (kWh) (LocBsdElectrFrGeothermalInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Location-Based Geothermal Mix Percentage (ElectricityEmssnFctrSet.LocBasedGeothermalMixPct)
Calculations
Location-Based Electricity from Geothermal (kWh) = Total Fuel Consumption (kWh) (where FuelType = “Electricity”) × ElectricityEmssnFctrSet.Location-Based Geothermal Mix Percentage/100
-
-
Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Biomass Mix Percentage (ElectricityEmssnFctrSet.MarketBasedBiomassMixPct)
-
Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
-
Renewable Energy Type (RenewableEnergyType)
Calculations
If Renewable Energy Type = “Biomass”, then Market-Based Electricity from Biomass (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Biomass Mix Percentage/100 + AllocatedRenewableEnergyInKwh.
If Renewable Energy Type ! = “Biomass”, then Market-Based Electricity from Biomass (kWh) = [Total Fuel Consumption (kWh) (Fuel Type = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Biomass Mix Percentage/100.
-
-
Market-Based Electricity from Coal (kWh) (MktBasedElectrFromCoalInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Coal Mix Percentage (ElectricityEmssnFctrSet.MarketBasedCoalMixPct)
-
Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
Calculations
Market-Based Electricity from Coal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Coal Mix Percentage/100
-
-
Market-Based Electricity from Gas (kWh) (MktBasedElectrFromGasInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Gas Mix Percentage (ElectricityEmssnFctrSet.MarketBasedGasMixPct)
-
Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
Calculations
Market-Based Electricity from Gas (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Electricity from Gas (kWh)/100
-
-
Market-Based Electricity from Hydro (kWh) (MktBasedElectrFromHydroInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Hydroelectric Mix Percentage (ElectricityEmssnFctrSet.MarketBasedHydroMixPct)
-
Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
-
Renewable Energy Type (RenewableEnergyType)
Calculations
If Renewable Energy Type = “Hydroelectricity”, then Market-Based Electricity from Hydro (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Hydroelectric Mix Percentage/100 + Allocated Renewable Energy (kWh).
If Renewable Energy Type ! = “Hydroelectricity”, then Market-Based Electricity from Hydro (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Hydroelectric Mix Percentage/100.
-
-
Market-Based Electricity from Nuclear (kWh) (MktBasedElectrFrNuclearInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Nuclear Mix Percentage (ElectricityEmssnFctrSet.MarketBasedNuclearMixPct)
Calculations
Market-Based Electricity from Nuclear (kWh) = [Total Fuel Consumption (kWh) (where FuelType = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Nuclear Mix Percentage/100.
-
-
Market-Based Electricity from Oil (kWh) (MktBasedElectrFromOilInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Oil Mix Percentage (ElectricityEmssnFctrSet.MarketBasedOilMixPct)
Calculations
Market-Based Electricity from Oil (kWh) = (Total Fuel Consumption (kWh) (FuelType = “Electricity”) – Allocated Renewable Energy (kWh)) × ElectricityEmssnFctrSet.Market-Based Oil Mix Percentage /100
-
-
Market-Based Electricity from Other Fuel (kWh) (MktBasedEnrgyFromOthrFuelInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Other Fuel Mix Percentage (ElectricityEmssnFctrSet.MarketBasedOtherFuelMixPct)
Calculations
Market-Based Electricity from Other Fuel (kWh) = [Total Fuel Consumption (kWh) (where FuelType = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Other Fuel Mix Percentage/100.
-
-
Market-Based Electricity from Solar (kWh) (MktBasedEnrgyFromSolarInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Solar Mix Percentage (ElectricityEmssnFctrSet.MarketBasedSolarMixPct)
-
Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
-
Renewable Energy Type (RenewableEnergyType)
Calculations
If RenewableEnergyType = “Solar”, then Market-Based Electricity from Solar (kWh) = [Total Fuel Consumption (kWh) (where FuelType = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Solar Mix Percentage/100 + Allocated Renewable Energy (kWh).
If RenewableEnergyType ! = “Solar”, then Market-Based Electricity from Solar (kWh) = [Total Fuel Consumption (kWh) (where FuelType = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Solar Mix Percentage/100.
-
-
Market-Based Electricity from Wind (kWh) (MktBasedEnrgyFromWindInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Wind Mix Percentage (ElectricityEmssnFctrSet.MarketBasedWindMixPct)
-
Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
-
Renewable Energy Type (RenewableEnergyType)
Calculations
If RenewableEnergyType = “Wind”, then Market-Based Electricity from Wind (kWh) = [Total Fuel Consumption (kWh) (where FuelType = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Wind Mix Percentage/100 + Allocated Renewable Energy (kWh).
If RenewableEnergyType ! = “Wind”, then Market-Based Electricity from Wind (kWh) = [Total Fuel Consumption (kWh) (FuelType = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Wind Mix Percentage/100.
-
-
Market-Based Electricity from Non-Renewables (kWh) (MktBsdEnrgyFrNonRenewablesKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Market-Based Energy from Biomass (kWh) (MktBasedEnrgyFromBiomassInKwh)
-
Market-Based Energy from Hydro (kWh) (MktBasedEnrgyFromHydroInKwh)
-
Market-Based Energy from Solar (kWh) (MktBasedEnrgyFromSolarInKwh)
-
Market-Based Energy from Wind (kWh) (MktBasedEnrgyFromWindInKwh)
-
Market-Based Energy from Geothermal (MktBsdEnrgyFromGeothermalInKwh)
Calculations
Market-Based Electricity from Non-Renewables (kWh) = Total Fuel Consumption (kWh) – Market-Based Energy from Biomass (kWh) – Market-Based Energy from Hydro (kWh) – Market-Based Energy from Solar (kWh) – Market-Based Energy from Wind (kWh) – Market-Based Energy from Geothermal
-
-
Market-Based Electricity from Geothermal (kWh) (MktBsdEnrgyFromGeothermalInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Geothermal Mix Percentage (ElectricityEmssnFctrSet.MktBasedGeothermalMixPct)
-
Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
-
Renewable Energy Type (RenewableEnergyType)
Calculations
If Renewable Energy Type = “Geothermal”, then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100 + Allocated Renewable Energy (kWh).
If Renewable Energy Type ! = “Geothermal”, then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100.
-
-
Market-Based Electricity from Other Fuel (kWh) (MktBasedElectrOthrFuelInKwh)
Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Electricity Emissions Factor Set.Market-Based Other Fossil Fuel Mix Percentage (ElectricityEmssnFctrSet.MktBasedOtherFossilFuelMixPct)
Calculations
Market-Based Electricity from Other Fuel (kWh) = [Total Fuel Consumption (kWh) (where FuelType = “Electricity”) – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Other Fossil Fuel Mix Percentage/100.
-
-
Scope 3 Downstream Emissions (tCO2e) (Scope3DnstrmEmissionsIntCO2e)
Input Fields
-
Other Emissions Factors (OtherEmissionFactors)
-
Supplemental Scope 3 Downstream Emissions (SuplScope3DnstrmEmissions)
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Stationary Asset Environmental Source (StnryAssetEnvrSrc)
Calculations
If the scope allocation for the fuel is scope 3 downstream, then perform this calculation.
For more information, see the calculations for Scope 1 Emissions (tCO2e).
Default Value
Scope3DnstrmEmissionsIntCO2e = SuplScope3DnstrmEmissions
-
-
Scope 3 Upstream Emissions (tCO2e) (Scope3UpstrmEmissionsInTco2e)
Input Fields
-
Other Emissions Factors (OtherEmissionFactors)
-
Supplemental Scope 3 Upstream Emissions (SuplScope3UpstrmEmissions)
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Stationary Asset Environmental Source (StnryAssetEnvrSrc)
Calculations
If the scope allocation for the fuel is scope 3 upstream, then perform this calculation.
For more information, see the calculations for Scope 1 Emissions (tCO2e).
Default Value
Scope 3 Upstream Emissions (tCO2e) = Supplemental Scope 3 Upstream Emissions
-
-
CH4 Emissions (kg) (Ch4EmissionsInKg)Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
-
Other Emissions Factor Set (OtherEmssnFctrSet)
-
Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
Fuel Type (FuelType)
CH4 Emissions Factor (Ch4EmissionFactor)
- Electricity Emission Factor Set (ElectricityEmssnFctrSet)
CH4 Emissions Rate (Ch4EmissionRate)
Calculations
If Fuel Type = "Electricity"
- CH4 Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.CH4 Emissions Rate × 1000/1000000.0
Default = 0
For any fuel other than refrigerants and electricity
- If CH4 Emissions Factor is in energy units
CH4 Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.CH4 Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.CH4 Emissions Factor is converted to Kg/Kwh
- Else CH4 Emissions (kg) = 0
-
-
CO2 Emissions (kg) (Co2EmissionsInKg)Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
-
Other Emissions Factor Set (OtherEmssnFctrSet)
-
Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
Fuel Type (FuelType)
CO2 Emissions Factor (Co2EmissionFactor)
- Electricity Emission Factor Set ()
CO2e Emissions Rate (Co2eEmissionRate)
Calculations
If Fuel Type = "Electricity"
- CO2 Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.CO2e Emissions Rate × 1000/1000.0
Default = 0
For any fuel other than refrigerants and electricity
- If CO2 Emissions Factor is in energy units
CO2 Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.CO2 Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.CO2 Emissions Factor is converted to Kg/Kwh
- Else CO2 Emissions (kg) = 0
-
-
N2O Emissions (kg) (N2oEmissionsInKg)Input Fields
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
- Fuel Type (FuelType)
-
Other Emissions Factor Set (OtherEmssnFctrSet)
-
Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
Fuel Type (FuelType)
N2O Emissions Factor (N2oEmissionFactor)
- Electricity Emission Factor Set ()
CH4 Emissions Rate (Ch4EmissionRate)
Calculations
If Fuel Type = "Electricity"
- N2O Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.CH4 Emissions Rate × 1000/1000000.0
Default = 0
For any fuel other than refrigerants and electricity
- If N2O Emissions Factor is in energy units
N2O Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.N2O Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.N2O Emissions Factor is converted to Kg/Kwh
- Else N2O Emissions (kg) = 0
-