Newer Version Available

This content describes an older version of this product. View Latest

EhrAllergyIntolerance__c to AllergeyIntolerance

Fields in EhrAllergyIntolerance__c map to AllergyIntolerance and PatientHealthReaction in the Clinical data model.
Ehr​Allergy​Intolerance​__c Field Description Clinical Data Model Field Notes
Account​__c
The person account that represents the patient in Lightning Platform.
Allergy​Intolerance​.PatientId N/A
Criticality​Code__c
The system-defined code that represents an estimate of the potential clinical harm or seriousness of the reaction to the identified substance.
Allergy​Intolerance​.Severity While EhrAllergyIntolerance__c uses a flattened code field that’s split into a set of three text fields, AllergyIntolerance uses a single picklist field instead.
Criticality​Label__c
The human-readable label that represents an estimate of the potential clinical harm or seriousness of the reaction to the identified substance.
Criticality​System__c
The system that defines an estimate of the potential clinical harm or seriousness of the reaction to the identified substance.
Is​Restricted​__c
Indicates whether or not this field has restricted visibility based on sharing rules.
Not Supported N/A
Is​Visible​On​Patient​Card​__c
Indicates whether or not this field appears on the patient card.
Not Supported N/A
Name
The EHR allergy intolerance ID. Limit: 255 characters.
Allergy​Intolerance​.Name N/A
Patient__c
The patient who has the sensitivity. Lookup to EhrPatient__c.
Allergy​Intolerance​.PatientId N/A
Reaction255__c
A description of the allergic reaction, including details of the manifestation if required. Limit: 255 characters.
Patient​Health​Reaction​.Details N/A
Reaction__c
A long text description of the allergic reaction, including details of the manifestation if required.
Not supported. The clinical data model field supports only up to 255 characters.
Recorded​Date__c
The date when the sensitivity was recorded.
Allergy​Intolerance​.Record​Creation​Date​Time N/A
Recorder​Name255__c
The name of the individual who recorded the record and takes responsibility for its content. Limit: 255 characters.
Person​Name​.Full​Name The Person​Name record associated to the person account representing the individual.
Recorder​Name__c
The long text description of the name of the individual who recorded the record and takes responsibility for its content.
Recorder__c
The individual who takes responsibility for the content and can reference its source. Lookup to EhrPractitioner__c.
Allergy​Intolerance​.Record​Creator​Id EhrAllergy​Intolerance references Ehr​Practitioner, Allergy​Intolerance references Account and Healthcare​Provider.
Sensitivity​Test1__c
An observation that confirms or refutes the patient’s sensitivity. Lookup to EhrObservation__c.
Not Supported Sensitivity is not specified as per FHIR R4. Consider creating a custom field that references Care​Observation if your organization needs to record this information.
Sensitivity​Test2__c
An observation that confirms or refutes the patient’s sensitivity. Lookup to EhrObservation__c.
Sensitivity​Test3__c
An observation that confirms or refutes the patient’s sensitivity. Lookup to EhrObservation__c.
Sensitivity​Type​Code__c
The system-defined code that represents the patient’s sensitivity.
Not Supported Sensitivity is not specified as per FHIR R4. Consider creating a custom field that references Code​Set​Bundle if your organization needs to record this information.
Sensitivity​Type​Label__c
The human-readable label that represents the patient’s sensitivity
Sensitivity​Type​System__c
The system that defines the patient’s sensitivity
Source​System__c
The external system of record for the allergy intolerance.
Allergy​Intolerance​.Source​System N/A
Source​SystemId__c
The ID of the record in the source system.
Allergy​Intolerance​.Source​System​Identifier N/A
Source​System​Modified__c
The date and time when the record was last modified in the source system.
Allergy​Intolerance​.Source​System​Modified N/A
Status​Code__c
The system-defined code that represents the level of certainty associated with the potential risk of a reaction to the identified substance.
Allergy​Intolerance​.Status While EhrAllergyIntolerance__c uses a flattened code field that’s split into a set of three text fields, AllergyIntolerance uses a single picklist field instead.
Status​Label__c
The human-readable label that represents the level of certainty associated with the potential risk of a reaction to the identified substance.
Status​System__c
The system that defines the level of certainty associated with the potential risk of a reaction to the identified substance.
Substance​255__c
The substance or class of substances that’s considered responsible for the adverse reaction risk. Limit: 255 characters.
Allergy​Intolerance​.Causative​Substance​Id Allergy​Intolerance uses a lookup to Code​Set​Bundle to represent substances as Codeable​Concept data.
Substance​Long​__c
The long text description of the substance or class of substances that’s considered responsible for the adverse reaction risk.
Substance​Code​__c
The system-defined code that represents the substance responsible for the reaction.
Substance​Code​System​__c
The system that defines the code that represents the substance that caused the reaction.