Note: This release is in preview. Features described here don’t become generally available until the latest general availability date that Salesforce announces for this release. Before then, and where features are noted as beta, pilot, or developer preview, we can’t guarantee general availability within any particular time frame or at all. Make your purchase decisions only on the basis of generally available products and features.
Device
The Device FHIR resource maps to the Asset and CareRegisteredDevice objects in Salesforce.
FHIR V4.0 - Clinical Data Model Mapping
Here’s how the fields defined by FHIR for Device map to the fields in Salesforce.
| Device Resource | Salesforce Field | Type | Salesforce Cardinality | Notes |
|---|---|---|---|---|
| identifier | Identifier | Object | 0.M | The identifier information for a device is represented as Identifier records that reference the CareRegisteredDevice record using their Identifier.ParentRecordId field. |
| uidCarrier.DeviceIdentifier | CareRegisteredDevice.UniqueDeviceId1 | External Lookup | 0.3 | While FHIR defines uidCarrier.DeviceIdentifier as a zero-to-many value, the Salesforce implementation supports a maximum of three values using three fields. |
| CareRegisteredDevice.UniqueDeviceId2 | External Lookup | |||
| CareRegisteredDevice.UniqueDeviceId3 | External Lookup | |||
| uidCarrier.Issuer | CareRegisteredDevice.UniqueDeviceId1Issuer | URL | 0.3 | While FHIR defines uidCarrier.Issuer as a zero-to-many value, the Salesforce implementation supports a maximum of three values using three fields. |
| CareRegisteredDevice.UniqueDeviceId2Issuer | URL | |||
| CareRegisteredDevice.UniqueDeviceId3Issuer | URL | |||
| uidCarrier.jurisdiction | N/A | N/A | N/A | Not supported |
| uidCarrier.carrierAIDC | N/A | N/A | N/A | Not supported |
| uidCarrier.arrierHRF | N/A | N/A | N/A | Not supported |
| uidCarrier.entryType | N/A | N/A | N/A | Not supported |
| status | Asset.Status | Picklist | 0.1 | While FHIR defines device.status as code, the Salesforce implementation is a picklist. |
| statusReason | Asset.StatusReason | Picklist | 0.1 | While FHIR defines device.statusReason as a zero-to-many codeable concept, the Salesforce implementation is a zero-to-one picklist. |
| distinctIdentifier | Asset.Uuid | String | 0.1 | N/A |
| manufacturer | Asset.AssetProviderBy | Lookup: Account | 0.1 | While FHIR defines device.manufacturer as string, the Salesforce implementation is a lookup to Account (Organization). |
| manufactureDate | Asset.ManufactureDate | Date | 0.1 | While FHIR defines device.manufactureDate as DateTime, the Salesforce implementation is a of the data type Date. |
| expirationDate | Asset.UsageEndDate | Date | 0.1 | While FHIR defines device.expirationDate as DateTime, the Salesforce implementation is a of the data type Date. |
| lotNumber | N/A | N/A | N/A | Not supported |
| serialNumber | Asset.SerialNumber | String | 0.1 | N/A |
| deviceName.name | CareRegisteredDevice.Name | String | 0.1 | While FHIR defines device.deviceName as a zero-to-many resource, the Salesforce implementation is zero-to-one. |
| deviceName.type | Lookup: CareRegisteredDevice.NameType | Multi-Select Picklist | 0.M | |
| modelNumber | Asset.ProductCode | String | 0.1 | N/A |
| partNumber | N/A | N/A | N/A | Not supported |
| type | CareRegisteredDevice.DeviceTypeId | Lookup: CodeSet | 0.1 | While FHIR defines device.type as a codeable concept value, the Salesforce implementation is a code set. |
| specialization | N/A | N/A | N/A | Not supported |
| version | N/A | N/A | N/A | Not supported |
| property | N/A | N/A | N/A | Not supported |
| patient | CareRegisteredDevice.PatientId | Lookup: Account | 0.1 | N/A |
| owner | Asset.AssetServicedBy | Lookup: Account | 0.1 | N/A |
| contact | CareRegisteredDevice.SupportContactDetail | String | 0.1 | While FHIR defines device.contact as a contact point value, the Salesforce implementation is a string. |
| location | N/A | N/A | N/A | N/A |
| url | Asset.Product2Id.DisplayUrl | URL | 0.1 | N/A |
| account | N/A | N/A | N/A | Not supported |
| note. | AuthorNote | Object | 0.M | The notes for a device are represented as AuthorNote records that reference the CareRegisteredDevice record using their AuthorNote.ParentRecordId field. |
| safety | CareRegisteredDevice.SafetyInformation | String | 0.1 | While FHIR defines device.safety as a codeable concept, the Salesforce implementation is a string field. |
| parent | Asset.ParentId | Lookup Asset | 0.1 | N/A |