Note: This release is in preview. Features described here don’t become generally available until the latest general availability date that Salesforce announces for this release. Before then, and where features are noted as beta, pilot, or developer preview, we can’t guarantee general availability within any particular time frame or at all. Make your purchase decisions only on the basis of generally available products and features.
Building Energy Intensity
Here are the calculated fields:
Input fields:
-
Stationary Asset Energy Use (StnryAssetEnrgyUse)
-
Start Date (StartDate)
-
End Date (EndDate)
-
Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
-
Occupied Floor Area (sqft) (OccupiedFloorAreaInSqft)
-
Fuel Type (FuelType)
-
-
Building Energy Intensity (BldgEnrgyIntensity)
-
Averaging Window Start Date (AveragingWindowStartDate)
-
Averaging Window End Date (AveragingWindowEndDate)
-
Output fields:
-
Building Energy Intensity (BldgEnrgyIntensity)
-
Annual Energy Intensity (kWh/sqft) (AnnualEnergyIntensityInKwhSqft)
-
Annual Energy Intensity (kWh/m2) (AnnualEnergyIntensityInKwhM2)
-
-
Building Energy Intensity Value (BldgEnrgyIntensityVal)
-
Annual Intensity Value (kWh/sqft) (AnnualIntensityValueInKwhSqft)
-
Annual Intensity Value (kWh/m2) (AnnualIntensityValueInKwhM2)
-
Calculations
-
For each Stationary Asset Energy Use
-
Number of days inside window = Input End Date - Input Start Date
Where:
-
Input Start Date = If(StnryAssetEnrgyUse.Start Date > BldgEnrgyIntensity.Averaging Window Start Date, StnryAssetEnrgyUse.Start Date, BldgEnrgyIntensity.Averaging Window Start Date)
-
Input End Date = If(StnryAssetEnrgyUse.End Date < BldgEnrgyIntensity.Averaging Window End Date, StnryAssetEnrgyUse.End Date, BldgEnrgyIntensity.Averaging Window End Date)
-
-
Reported days = StnryAssetEnrgyUse.End Date - StnryAssetEnrgyUse.Start Date
-
Intensity per sqft (kWh/sqft) = StnryAssetEnrgyUse.Total Fuel Consumption In Kwh / StnryAssetEnrgyUse.Occupied Floor Area In Sqft
-
Intensity per sqft per day (kWh/sqft/day) = Intensity per sqft / Reported days
-
Intensity per sqft inside window (kWh/sqft) = Intensity per sqft per day * Number of days inside window
-
- For each Fuel Type
-
Total Energy Intensity (kWh/sqft) = SUM(Intensity per sqft inside window (kWh/sqft))
-
Total Days = SUM(Number of days inside window)
-
- For each Fuel Type
-
Total Energy Intensity per Day (kWh/sqft/day) = Total Energy Intensity (kWh/sqft) / Total Days
-
BldgEnrgyIntensityVal.Annual Intensity Value (kWh/sqft) = Total Energy Intensity per Day (kWh/sqft/day) * 365
-
BldgEnrgyIntensityVal.Annual Intensity Value (kWh/m2) = BldgEnrgyIntensityVal.Annual Intensity Value (kWh/sqft) * 0.092903
-
- For Building Energy Intensity
-
BldgEnrgyIntensity.Annual Intensity Value (kWh/sqft) = SUM(BldgEnrgyIntensityVal.Annual Intensity Value (kWh/sqft))
-