The Generated Waste object represents the information on the waste generated in operations, the waste generated while treating end-of-life products that were sold, and so on.
Here are the calculated fields:
Disposed Waste Quantity in Tonnes (DisposedWasteQuantityinTonnes)
Input Fields
Disposed Waste Quantity (DisposedWasteQuantity)
Disposed Waste Quantity Unit (DisposedWasteQuantityUnit)
Calculations
If Disposed Waste Quantity Unit = lb, then Disposed Waste Quantity in Tonnes = Disposed Waste Quantity × 0.000454.
If Disposed Waste Quantity Unit = kg, then Disposed Waste Quantity in Tonnes = Disposed Waste Quantity × 0.001.
If Disposed Waste Quantity Unit = Short Ton, then Disposed Waste Quantity in Tonnes = Disposed Waste Quantity × 0.9072.
If Disposed Waste Quantity Unit = Long Ton, then Disposed Waste Quantity in Tonnes = Disposed Waste Quantity × 1.016.
If Disposed Waste Quantity Unit = Tonne, then Disposed Waste Quantity in Tonnes = Disposed Waste Quantity.
Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e) (Scp3UpstrmWstGenInOper)
Input Fields
Emissions Factor Value (tCO2e/Tonne Waste Material) (WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.EmssnFctrTco2eTonneWstMtrl)
Waste Type (WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.WasteType)
Disposal Type(WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.DisposalType)
Waste Type (GeneratedWaste.WasteType)
Disposal Type (GeneratedWaste.DisposalType)
Disposal Site Type (GeneratedWaste.DisposalSiteType)
Stationary Asset Environmental Source (GeneratedWaste.StnryAssetEnvrSrc)
Supplemental Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e) (SuplScp3UpstrmWstGenInOper)
Disposed Waste Quantity in Tonnes (DisposedWasteQuantityinTonnes)
Scope 3 Downstream Emissions from End-of-Life Treatment of Sold Products (tCO2e) (Scp3DnstrmEndLifeSoldPrdct)
Scope 1 Emissions (tCO2e) (Scope1EmissionsInTco2e)
Calculations
Var A = WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.Emissions Factor Value (tCO2e/Tonne Waste Material) where (WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.Waste Type = GeneratedWaste.Waste Type and WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.Disposal Type = GeneratedWaste.Disposal Type)
If StnryAssetEnvrSrc isn’t Null and Disposal Site Type = Offsite, then
Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e) = A × GeneratedWaste.Disposed Waste Quantity in Tonnes + Supplemental Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e) and Scope 3 Downstream Emissions from End-of-Life Treatment of Sold Products (tCO2e) = Null or Zero and Scope 1 Emissions (tCO2e) = Null or Zero.
Else, Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e) = Supplemental Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e).
Scope 3 Downstream Emissions from End-of-Life Treatment of Sold Products (tCO2e) (Scp3DnstrmEndLifeSoldPrdct)
Input Fields
Emissions Factor Value (tCO2e/Tonne Waste Material) (WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.EmssnFctrTco2eTonneWstMtrl)
Waste Type (WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.WasteType)
Disposal Type(WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.DisposalType)
Waste Type (GeneratedWaste.WasteType)
Disposal Type (GeneratedWaste.DisposalType)
Scope 3 Emissions Source (GeneratedWaste.Scope3EmssnSrc)
Disposed Waste Quantity in Tonnes (GeneratedWaste.DisposedWasteQuantityinTonnes)
Supplemental Scope 3 Downstream Emissions from End-of-Life Treatment of Sold Products (tCO2e) (GeneratedWaste.SuplScp3DnstrmEndLifeSoldPrdct)
Supplemental Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e) (GeneratedWaste.SuplScp3UpstrmWstGenInOper)
Scope 1 Emissions (tCO2e) (GeneratedWaste.Scope1EmissionsInTco2e)
Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e) (GeneratedWaste.Scp3UpstrmWstGenInOper)
Calculations
Var A = WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.Emissions Factor Value (tCO2e/Tonne Waste Material) where (WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.Waste Type = GeneratedWaste.Waste Type and WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.Disposal Type = GeneratedWaste.Disposal Type)
If Scope 3 Emissions Source isn’t Null, then
Scope 3 Downstream Emissions from End-of-Life Treatment of Sold Products (tCO2e) = A × GeneratedWaste.Disposed Waste Quantity in Tonnes + Supplemental Scope 3 Downstream Emissions from End-of-Life Treatment of Sold Products (tCO2e) and Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e) = Null and Scope 1 Emissions (tCO2e) = Null
Else, Scope 3 Downstream Emissions from End-of-Life Treatment of Sold Products (tCO2e) = Supplemental Scope 3 Downstream Emissions from End-of-Life Treatment of Sold Products (tCO2e).
Scope 1 Emissions (tCO2e) (Scope1EmissionsInTco2e)
Input Fields
Emissions Factor Value (tCO2e/Tonne Waste Material) (WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.EmssnFctrTco2eTonneWstMtrl)
Waste Type (WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.WasteType)
Disposal Type(WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.DisposalType)
Waste Type (GeneratedWaste.WasteType)
Disposal Type (GeneratedWaste.DisposalType)
Disposal Site Type (GeneratedWaste.DisposalSiteType)
Stationary Asset Environmental Source (GeneratedWaste.StnryAssetEnvrSrc)
Supplemental Scope 1 Emissions (tCO2e) (GeneratedWaste.SuplScope1EmissionsInTco2e)
Disposed Waste Quantity in Tonnes (GeneratedWaste.DisposedWasteQuantityinTonnes)
Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e) (GeneratedWaste.Scp3UpstrmWstGenInOper)
Scope 3 Downstream Emissions from End-of-Life Treatment of Sold Products (tCO2e) (Scp3DnstrmEndLifeSoldPrdct)
Calculations
Var A = WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.Emissions Factor Value (tCO2e/Tonne Waste Material) where (WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.Waste Type = GeneratedWaste.Waste Type and WstDispoEmssnFctr.WstDispoEmssnFctrSetItm.Disposal Type = GeneratedWaste.Disposal Type)
If StnryAssetEnvrSrc isn’t Null and Disposal Site Type = Onsite, then
Scope 1 Emissions (tCO2e) = A × GeneratedWaste.Disposed Waste Quantity in Tonnes + Supplemental Scope 1 Emissions (tCO2e) and Scope 3 Upstream Emissions from Waste Generated in Operations (tCO2e) = Null and Scope 3 Downstream Emissions from End-of-Life Treatment of Sold Products (tCO2e) = Null.
Else, Scope 1 Emissions (tCO2e) = Supplemental Scope 1 Emissions (tCO2e).