Model Structure

The tables on the following pages show the structure for the constraint model in Core Concept Examples.

See Core Concept Examples.

LevelProduct GroupProductProduct Type NameProduct AttributeAPI Name OR CML VariableConfigurable or StaticTypeComments
0BundleGenerator SetGeneratorSet     
    Required KWrequiredKWCONFIGURABLEint 
    Surge Load KWsurgeLoadKWEXPRESSIONdecimalrequiredKW * 1.25
    Reserve Capacity KWreserveCapacityKWEXPRESSIONdecimalsurgeLoadKW - requiredKW
    VoltagevoltageCONFIGURABLEPicklist Voltage [“220/380”,“240/416”,“255/440”,“277/480”,“347/600”,“2400/4160”,“7200/12470”,“7621/13200”,“7976/13800”] 
    Duty RatingdutyRatingCONFIGURABLEPicklist DutyRating [“Prime Power”, “Continuous Power”, “Data Center Continuous”, “Emergency Standby Power”] 
    Standards and CompliancestandardsAndCompliance Picklist standardsAndCompliance [“Certification-CSA”, “Listing-UL 2200”] 
    max dB leveldBMaxCONFIGURABLEint 
    Nominal Power OutputnominalPowerOutput Picklist Power Output Picklist [“100 kW”, “300 kW”, “500 kW”, “700 kW”] 
1General       
2General - Model GeneralModel     
    Power KWpowerKWSTATICPicklist powerKW [900, 1750, 2500]powerKW >= Needs.requiredKW
    dBdBSTATICPicklist dB [78, 90, 94] 
  General Model 900GeneralModel900     
  General Model 1750GeneralModel1750     
  General Model 2500GeneralModel2500     
2General - Voltage Connection VoltageConnection     
    VoltagevoltageSTATICPicklist voltage [“220/380”, “240/416”, “255/440”]voltage == Needs.voltage
    Cable EntrycableEntryCONFIGURABLEPicklist cableEntry [“Top Entry”, “Bottom Entry”, “Side Entry”] 
  220/380,3 Phase,Wye,4 WireVoltageConnection_220_380     
  240/416,3 Phase,Wye,4 WireVoltageConnection_240_416     
  255/440,3 Phase,Wye,4 WireVoltageConnection_255_440     
1Alternator       
2Alternator - Main Alternator MainAlternator     
     voltageSTATICPicklist VoltageNeeds.voltage == voltage
     PRPSTATICbooleanconstraint(Needs.dutyRating==“Prime Power”->PRP==true)
     COPSTATICbooleanconstraint(Needs.dutyRating==“Continuous Power”->COP==true)
     DCCSTATICbooleanconstraint(Needs.dutyRating==“Data Center Continuous”->DCC==true)
     ESPSTATICbooleanconstraint(Needs.dutyRating==“Emergency Standby Power”->ESP==true)
  Alt-60Hz,Wye,220/380V,150/125/105C-SD/P/C,40C ambFESBA_B595_2     
  Alternator-60Hz,Wye,240/416 Volt,105/80C-StbyPrmFESBA_B715_2     
  Alt-60Hz,Wye,440V,150/125SP,40C ambFESBA_B691_2     
2Alternator - Heater       
2Alternator - Temperature Sensors TemperatureSensor     
    Max Operating KWmaxOperatingKWSTATIC  
    Parent Required KWparentRequiredKWEXPRESSION  
  Temp Sens-Stator, 2 RTD/PhStatorTemperatureSensor     
  Bearing,1 RTD NDEBearingTemperatureSensor     
2Alternator - Output Terminals OutputTerminal     
  Output Terminals-2-Hole Lug, NEMAOutputTerminals2HoleLugNEMA     
1Engine       
2Engine - Engine Model EngineModel     
  Engine - QSK60-G6FESBA_2940     
2Engine - Starter Motor StarterMotor     
  Electric Starter Motor - 24V DCFESBA_A334-2     
2Engine - Fuel Filter FuelFilter     
  Fuel Filters-Engine, StandardFESBA_3090     
  Fuel Filters-Engine, DuplexFESBA_C278-2     
1Control       
2Control - Control Main Control     
    Control PlacementcontrolPlacementCONFIGURABLEPicklist [“Left”, “Right”, “Top”] 
    Commissioning ScopecommissioningScopeCONFIGURABLEPicklist [“None”, “Remote Support”, “On-site Commissioning”] 
    Control LanguagecontrolLanguageCONFIGURABLEPicklist [“English”, “Danish”, “French”] 
  PowerCommand 3.3FESBA_H704_2     
  PowerCommand 3.3 with MLDFESBA_KX21_2     
2Control - Control Cabinet Heater ControlCabinetHeater     
  120/240VAC compatibleFESBA_A460_2     
1Services       
2Services - Warranty Warranty     
  Warranty PRPWarranty_PRP     
  Warranty DCCWarranty_DCC     
  Warranty ESPWarranty_ESP     
2Services - Maintenance Maintenance     
    Maintenance DurationmaintenanceDurationCONFIGURABLEint [12..60] 
    Coverage LevelcoverageLevelCONFIGURABLEPicklist [“Standard”, “Premium”] 
  Standard Maintenance KitStandardMaintenanceKit     
2Services - Testing Test     
  Test - Standard FactoryStandardFactoryTest     
  Test Record-CertifiedTestRecord     
  Test-Independent LaboratoryIndependentLaboratoryTest     
  Test - WitnessWitnessTest     
  Test-Extended, Standby Load, 2WitnessTestService     
1Accessories       
2Accessories - Main Accessory     
    CategorycategoryCONFIGURABLEPicklist 
    Weightweight   
2Accessories - Enclosure Enclosure     
    dB ReductiondBReductionSTATICPicklist dBReduction [0, 1, 3, 6, 9] 
  Enclosure NoneEnclosure_None     
  Enclosure WeatherEnclosure_Weather     
  Enclosure SA1Enclosure_SA1     
  Enclosure SA2Enclosure_SA2     
  Enclosure SA3Enclosure_SA3     
1Install & Misc       
2Install & Misc - Installation install