Newer Version Available

This content describes an older version of this product. View Latest

Stationary Asset Energy Use

The Stationary Asset Energy Use object represents the energy consumption related to stationary assets across multiple fuel types.

Permission Set Needed
To enter and modify data: Net Zero Cloud Manager

OR

Net Zero Cloud Admin

Table 1. Fuel Consumption (kWh) Units by Fuel Type
Fuel Units Electricity Cooling Diesel Fuel Oil/Heavy Oil Heat Natural Gas Liquid Natural Gas (LNG) Propane Steam Light Oil Kerosene City Gas Refrigerant
kWh
GWh
MWh
GJ
MJ
kcal
MMBtu
Therm
Kg
lbs
Tonnes
Short Tons
Long Tons
US Gallon
UK Gallon
Liter
Kiloliters
m3
1000 m3
ccf

Allocate the default scope for the fuel. Depending on the scope, the relevant fields are populated and the other fields default to 0:

  • Scope 1 Emissions (tCO2e).
  • Scope 2 Location-Based Emissions (tCO2e) and Scope 2 Market-Based Emissions (tCO2e). Scope 2 means both these fields are populated.
  • Scope 3 Downstream Emissions (tCO2e).
  • Scope 3 Upstream Emissions (tCO2e).

If you have not associated a scope allocation, then use the default scope allocations.

Fuel Company-Owned Asset = Yes Company-Owned Asset = No
Electricity Scope 2 Scope 3 Upstream Leased Assets
City Gas Scope 1 Scope 3 Upstream Leased Assets
Cooling Scope 2 Scope 3 Upstream Leased Assets
Diesel Scope 1 Scope 3 Upstream Leased Assets
Fuel Oil Scope 1 Scope 3 Upstream Leased Assets
Heat Scope 2 Scope 3 Upstream Leased Assets
Heavy Oil Scope 1 Scope 3 Upstream Leased Assets
Kerosene Scope 1 Scope 3 Upstream Leased Assets
Light Oil Scope 1 Scope 3 Upstream Leased Assets
Liquid Natural Gas Scope 1 Scope 3 Upstream Leased Assets
Natural Gas Scope 1 Scope 3 Upstream Leased Assets
Propane Scope 1 Scope 3 Upstream Leased Assets
Refrigerant Scope 1 Scope 3 Upstream Leased Assets
Steam Scope 2 Scope 3 Upstream Leased Assets

For information about converting the values from one unit of measure to another compatible unit of measure, see Conversion Factors.

Here are the calculated fields:

  • Fuel Consumption (kWh) (FuelConsumptionInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Fuel Consumption (FuelConsumption)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)

      Fuel Type (FuelType)

      Calorific Value (CalorificValue)

      Calorific Value Unit (CalorificValueUnit)

    • Conversion constant

    Calculations

    If these fuels are measured in volume units:

    • City Gas
    • Diesel
    • Fuel Oil
    • Heavy Oil
    • Kerosene
    • Light Oil
    • Liquid Natural Gas (LNG)
    • Natural Gas
    • Propane
    • Biomass

    Then to convert the volume to energy units:

    Fuel Consumption (kWh) = Fuel Consumption (converted to m3) × OtherEmssnFctrSet.OtherEmssnFctrSetItem.Calorific Value (converted to kWh/m3) and Fuel Type = OtherEmssnFctrSet.OtherEmssnFctrSetItem.Fuel Type

  • Fuel Consumption (GJ) (FuelConsumptionInGigajoule)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Conversion constant

    Calculations

    Fuel Consumption (GJ) = Total Fuel Consumption (kWh)/277.7777777

  • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)

    Input Fields

    • Fuel Consumption (kWh) (FuelConsumptionInKwh)
    • Power Usage Effectiveness (PowerUsageEffectiveness)

    Calculations

    If Record Type = "Data Center", then Total Fuel Consumption (kWh) = Fuel Consumption (kWh) × Power Usage Effectiveness.

    else, for all other fuel types and record types, Total Fuel Consumption (kWh) = Fuel Consumption (kWh).

  • Occupied Floor Area (sqft) (OccupiedFloorAreaInSqft)

    Input Fields

    • Occupied Floor Area (OccupiedFloorArea)
    • Occupied Floor Area Unit (OccupiedFloorAreaUnit)
    • Conversion constant

    External Object Calculations

    If Occupied Floor Area Unit = "sqft", then Occupied Floor Area (sqft) = Occupied Floor Area.

    If Occupied Floor Area Unit = "m2", then Occupied Floor Area (sqft) = Occupied Floor Area × 10.76391042.

  • Scope 1 Emissions (tCO2e) (Scope1EmissionsInTco2e)

    Input Fields

    • Other Emissions Factors (OtherEmssnFctrId)
    • Supplemental Scope 1 Emissions (SuplScope1Emissions)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    • If Carbon Emission Scope Allocation = "Scope 1"

      or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation = "Scope 1" ( where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type )

      If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

      Note

    • If Fuel Type = "Electricity", then Scope 1 Emissions (tCO2e) = (Total Fuel Consumption (kWh)) × ElectricityEmssnFctrSet.CO2e Emissions Rate (tonnes/MWh)/1000 + Supplemental Scope 1 Emissions.
    • For any fuel other than refrigerants and electricity,

      If (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor = 0) then Scope 1 Emissions (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.CO2e Emissions Factor (tCO2e/MWh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 1 Emissions

      else if (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor != 0) then Scope 1 Emissions (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor (convert to Kg/Kwh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 1 Emissions.

    • If FuelType = "Refrigerant", then Scope 1 Emissions (tCO2e) = FuelConsumption (converted to Kgs) × RefrigerantEmssnFctr.Global Warming Potential/1000 + Supplemental Scope 1 Emission

    Default Value

    Scope 1 Emissions (tCO2e) = Supplemental Scope 1 Emissions

  • Scope 2 Location-Based Emission (tCO2e) (Scope2LocBasedEmssnInTco2e)

    Input Fields

    • Other Emissions Factors (OtherEmssnFctrId)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factors (ElectricityEmissionFactorsId)
    • Company-Owned Asset (IsCompanyOwnedAsset)
    • Supplemental Scope 2 Location-Based Emissions (SuplScope2LocationBasedEmssn)
    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    • If Carbon Emission Scope Allocation = "Scope 2"

      or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation = "Scope 2" (where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type)

      If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

      Note

    • If Fuel Type = "Electricity" then Scope 2 Location-Based Emission (tCO2e) =(Total Fuel Consumption (kWh) ) × Electricity Emissions Factor Set.Co2eEmissionRateInTmwh / 1000 + SuplScope2LocationBasedEmssn
    • For any fuel other than refrigerants and Electricity

      If (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor = 0) then Scope 2 Location-Based Emission (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.CO2e Emissions Factor (tCO2e/MWh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Location-Based Emissions

      else if (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor != 0) then Scope 2 Location-Based Emission (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor (convert to Kg/Kwh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Location-Based Emissions

    • If Fuel Type="Refrigerant" then Scope 2 Location-Based Emission (tCO2e) = Fuel Consumption (converted to Kgs) × RefrigerantEmssnFctr.Global Warming Potential/1000 + Supplemental Scope 2 Location-Based Emissions

    Default Value

    Scope 2 Location-Based Emission (tCO2e) = Supplemental Scope 2 Location-Based Emissions

  • Scope 2 Market-Based Emission (tCO2e) (Scope2MktBasedEmssnInTco2e)

    Input Fields

    • Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
    • Company-Owned Asset (IsCompanyOwnedAsset)
    • Electricity Emissions Factors (ElectricityEmissionFactorsId)
    • Emissions Factor Type (EmissionsFactorType)
    • Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
    • Emissions Factor Type (EmissionsFactorType)
    • Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
    • Supplemental Scope 2 Market-Based Emissions (SuplScope2MarketBasedEmssn)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Renewable Energy Type Override (RenewableEnergyType)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)
    • Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
    • Clean Energy Project (CleanEnergyProject)
    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    If Carbon Emission Scope Allocation = "Scope 2"

    or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation = "Scope 2" ( where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type)

    If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

    Note

    • If Renewable Energy Type Override ! = Empty, then Scope 2 Market-Based Emissions (tCO2e) = ((Total Fuel Consumption (kWh) - Allocated Renewable Energy Override (kWh) ) × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000))

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None) (MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000))

      else 0))

      When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object,

      if Renewable Energy Type Override == Empty (None),

      then Scope 2 Market-Based Emissions (tCO2e) =(Total Fuel Consumption (kWh) - Allocated Energy Attribute Credits (kWh)] ) × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000)))

      else if (MktBsdElectriEmssnFctrId.Emissions Factor Type == LocationAndMarketBased or None) (MktBsdElectriEmssnFctrId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000))

      else 0+ Supplemental Scope 2 Market-Based Emissions) + for each Energy Attribute Credit Distribution associated with this record if (EnergyAttrCreditDstr.EnergyAttrCertPurchase.CleanEnergyProject.Electricity Emissions Factors !=NULL (EnergyAttrCreditDstr.Allocated Energy Attribute Credits (kWh) × EnergyAttrCreditDstr.EnergyAttrCertPurchase.CleanEnergyProject.ElectrEmissionsFactorsId.Market-Based CO2e Emissions Rate (tonnes/MWh) / 1000))

    • For any fuel other than refrigerants and Electricity

      If (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor = 0) then Scope 2 Market-Based Emissions (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.CO2e Emissions Factor (tCO2e/MWh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Market-Based Emissions

      else if (Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor != 0) then Scope 2 Market-Based Emissions (tCO2e) = Total Fuel Consumption (kWh) × Other Emissions Factor Set.Other Emissions Factor Set Item.Supplied CO2e Emissions Factor (convert to Kg/Kwh) (Fuel Type = Other Emissions Factor Set.Other Emissions Factor Set Item.Fuel Type) / 1000 + Supplemental Scope 2 Market-Based Emissions

    • If FuelType="Refrigerant", Scope 2 Market-Based Emissions (tCO2e) = Fuel Consumption (converted to Kgs) × RefrigerantEmssnFctr.Global Warming Potential/1000 + Supplemental Scope 2 Market-Based Emissions

    Default Value

    Scope 2 Market-Based Emission (tCO2e) = Supplemental Scope 2 Market-Based Emissions

  • Market-Based CO2 Emissions (kg) (MktBsdCo2EmssnInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
      • Fuel Type (FuelType)
      • CO2 Emissions Factor (Co2EmissionFactor)
      • CO2 Emissions Factor Unit (Co2EmissionFactorUnit)
    • Electricity Emissions Factors (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)
    • Renewable Energy Type Override (RenewableEnergyType)
    • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)
    • Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
    • Clean Energy Project (CleanEnergyProject)
      • Market-Based CO2 Emissions Rate (tonnes/MWh) (MktBsdCo2EmssnRtInTmwh)

    Calculations

    if (Fuel Type == ELECTRICITY)

    {

    If (Renewable Energy Type Override!= Empty) { Market-Based CO2 Emissions (kg) = (Total Fuel Consumption (kWh) TotalFuelConsumptionInKwh - Allocated Renewable Energy Override (kWh)) * ElectricityEmssnFctrSet.Market-Based CO2 Emissions Rate (tonnes/MWh) }

    else { Market-Based CO2 Emissions (kg) = (Total Fuel Consumption (kWh) * ElectricityEmssnFctrSet.Market-Based CO2 Emissions Rate (tonnes/MWh)) }

    }

    Else { // Default calculation for all other fuel types

    Market-Based CO2 Emissions (kg) = 0

    }

  • Market-Based CH4 Emissions (kg) (MktBsdCh4EmssnInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
      • Fuel Type (FuelType)
      • CH4 Emissions Factor (Ch4EmissionFactor)
      • CH4 Emissions Factor Unit (Ch4EmissionFactorUnit)
    • Electricity Emission Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based CH4 Emissions Rate (tonnes/GWh) (MktBsdCh4EmssnRtInTgwh)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based CH4 Emissions Rate (tonnes/GWh) (MktBsdCh4EmssnRtInTgwh)
    • Renewable Energy Type Override (RenewableEnergyType)
    • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
      • Stationary Asset Energy Use (StnryAssetEnergyUseId)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)
    • Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)
    • Clean Energy Project (CleanEnergyProject)
      • Electricity Emissions Factors (ElectrEmissionsFactorsId)

        Market-Based CH4 Emissions Rate (tonnes/GWh) (MktBsdCh4EmssnRtInTgwh)

    Calculations

    if (Fuel Type == ELECTRICITY)

    {

    If (Renewable Energy Type Override!= Empty) { Market-Based CH4 Emissions (kg) = (Total Fuel Consumption (kWh) TotalFuelConsumptionInKwh - Allocated Renewable Energy Override (kWh)) * ElectricityEmssnFctrSet.Market-Based CH4 Emissions Rate (tonnes/GWh)/1000.0 } else { Market-Based CH4 Emissions (kg) = Total Fuel Consumption (kWh) * ElectricityEmssnFctrSet.Market-Based CH4 Emissions Rate (tonnes/GWh)/1000.0 }

    }

    Else { // Default calculation for all other fuel types

    Market-Based CH4 Emissions (kg) = 0

    }

  • Market-Based N2O Emissions (kg) (MktBsdN2oEmssnInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)
      • Fuel Type (FuelType)
      • N2O Emissions Factor (N2oEmissionFactor)
      • N2O Emissions Factor Unit (N2oEmissionFactorUnit)
    • Electricity Emission Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based N2O Emissions Rate (tonnes/GWh) (MktBsdN2oEmssnRtInTgwh)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based N2O Emissions Rate (tonnes/GWh) (MktBsdN2oEmssnRtInTgwh)
    • Renewable Energy Type Override (RenewableEnergyType)
    • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
      • Stationary Asset Energy Use (StnryAssetEnergyUseId)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)

      Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)

    • Clean Energy Project (CleanEnergyProject)
      • Electricity Emissions Factors (ElectrEmissionsFactorsId)
      • Market-Based N2O Emissions Rate (tonnes/GWh) (MktBsdN2oEmssnRtInTgwh)

    Calculations

    if (Fuel Type == ELECTRICITY)

    {

    If (Renewable Energy Type Override!= Empty) { Market-Based N2O Emissions (kg) = (Total Fuel Consumption (kWh) TotalFuelConsumptionInKwh - Allocated Renewable Energy Override (kWh)) * ElectricityEmssnFctrSet.Market-Based N2O Emissions Rate (tonnes/GWh)/1000.0 } else { Market-Based N2O Emissions (kg) = (Total Fuel Consumption (kWh) * ElectricityEmssnFctrSet.Market-Based N2O Emissions Rate (tonnes/GWh)/1000.0) }

    }

    Else { // Default calculation for all other fuel types

    Market-Based N2O Emissions (kg) = 0

    }

  • Total Floor Area (sqft) (TotalFloorAreaInSqft)

    Input Fields

    • Total Floor Area (TotalFloorArea)
    • Total Floor Area Unit (TotalFloorAreaUnit)
    • Conversion constant

    External Object Calculations

    If Total Floor Area Unit = "sqft", then Total Floor Area (sqft) = Total Floor Area.

    If Total Floor Area Unit = "m2", then Total Floor Area (sqft) = Total Floor Area × 10.76391042.

  • Total Renewable Energy (kWh) (TotalRenewableEnergyInKwh)

    Input Fields

    • Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
    • Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)
    • Market-Based Electricity from Hydro (kWh) (MktBasedElectrFromHydroInKwh)
    • Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
    • Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)

    Calculations

    Total Renewable Energy (kWh) = Market-Based Electricity from Biomass (kWh) + Market-Based Electricity from Geothermal (kWh) + Market-Based Electricity from Hydro (kWh) + Market-Based Electricity from Solar (kWh) + Market-Based Electricity from Wind (kWh)

    Default Value

    0

  • Total Renewable Energy Excluding Hydro (kWh) (TotRnwlEnrgyExclHydroInKwh)

    Input Fields

    • Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
    • Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)
    • Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
    • Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)

    Calculations

    Total Renewable Energy Excluding Hydro (kWh) = Market-Based Electricity from Biomass (kWh) + Market-Based Electricity from Geothermal (kWh) + Market-Based Electricity from Solar (kWh) + Market-Based Electricity from Wind (kWh)

    Default Value

    0

  • Power Usage Effectiveness Monthly Range (IsPueMonthlyRange)

    Input Fields

    • Power Usage Effectiveness (PowerUsageEffectiveness)
    • Record Type

    Calculations

    If Record Type = "Data Center":

    If Power Usage Effectiveness >= 1 and Power Usage Effectiveness <= 2, then Power Usage Effectiveness Monthly Range = TRUE.

    If Power Usage Effectiveness <1 or Power Usage Effectiveness > 2, then Power Usage Effectiveness Monthly Range = FALSE.

  • Normalized Monthly Electricity Consumption (kWh) (NormalizedMoElectrCnsmpInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • End Date (EndDate)
    • Start Date (StartDate)

    Calculations

    Normalized Monthly Electricity Consumption (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × [30/(End Date – Start Date + 1)]

  • Location-Based Electricity from Biomass (kWh) (LocBasedElectrFrBiomassInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Biomass Mix Percentage (ElectricityEmssnFctrSet.LocationBasedBiomassMixPct)

    Calculations

    Location-Based Electricity from Biomass (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Biomass Mix Percentage/100

  • Location-Based Electricity from Coal (kWh) (LocBasedElectrFrCoalInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Coal Mix Percentage (ElectricityEmssnFctrSet.LocationBasedCoalMixPct)

    Calculations

    Location-Based Electricity from Coal (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Coal Mix Percentage/100

  • Location-Based Electricity from Gas (kWh) (LocBasedElectrFrGasInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Gas Mix Percentage (ElectricityEmssnFctrSet.LocationBasedGasMixPct)

    Calculations

    Location-Based Electricity from Gas (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Gas Mix Percentage/100

  • Location-Based Electricity from Hydro (kWh) (LocBasedElectrFrHydroInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Hydro Mix Percentage (ElectricityEmssnFctrSet.LocationBasedHydroMixPct)

    Calculations

    Location-Based Electricity from Hydro (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Hydro Mix Percentage/100

  • Location-Based Electricity from Nuclear (kWh) (LocBasedElectrFrNuclearInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Nuclear Mix Percentage (ElectricityEmssnFctrSet.LocationBasedNuclearMixPct)

    Calculations

    Location-Based Electricity from Nuclear (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × Electricity Emissions Factor Set.Location-Based Nuclear Mix Percentage/100

  • Location-Based Electricity from Oil (kWh) (LocBasedElectrFrOilInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Oil Mix Percentage (ElectricityEmssnFctrSet.LocationBasedOilMixPct)

    Calculations

    Location-Based Electricity from Oil (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × ElectricityEmssnFctrSet.Location-Based Oil Mix Percentage/100

  • Location-Based Electricity from Other Fuel (kWh) (LocBasedElectrFrOthrFuelInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Other Fuel Mix Percentage (ElectricityEmssnFctrSet.LocationBasedOtherFuelMixPct)

    Calculations

    Location-Based Electricity from Other Fuel (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Other Fuel Mix Percentage/100

  • Location-Based Electricity from Solar (kWh) (LocBasedElectrFrSolarInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Solar Mix Percentage (ElectricityEmssnFctrSet.LocationBasedSolarMixPct)

    Calculations

    Location-Based Electricity from Solar (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Solar Mix Percentage/100

  • Location-Based Electricity from Wind (kWh) (LocBasedElectrFrWindInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Wind Mix Percentage (ElectricityEmssnFctrSet.LocationBasedWindMixPct)

    Calculations

    Location-Based Electricity from Wind (kWh) = Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") × ElectricityEmssnFctrSet.Location-Based Wind Mix Percentage/100

  • Location-Based Electricity from Non-Renewables (kWh) (LocBsdElectrFrNonRenewablesKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Location-Based Electricity from Biomass (kWh) (LocBasedElectrFrBiomassInKwh)
    • Location-Based Electricity from Hydro (kWh) (LocBasedElectrFromHydroInKwh)
    • Location-Based Electricity from Solar (kWh) (LocBasedElectrFromSolarInKwh)
    • Location-Based Electricity from Wind (kWh) (LocBasedElectrFromWindInKwh)
    • Location-Based Electricity from Geothermal (kWh) (LocBsdElectrFrGeothermalInKwh)

    Calculations

    Location-Based Electricity from Non-Renewable (kWh) = Total Fuel Consumption (kWh) – Location-Based Electricity from Biomass (kWh) – Location-Based Electricity from Hydro (kWh) – Location-Based Electricity from Solar (kWh) – Location-Based Electricity from Wind (kWh) – Location-Based Electricity from Geothermal (kWh)

  • Location-Based Electricity from Geothermal (kWh) (LocBsdElectrFrGeothermalInKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Geothermal Mix Percentage (ElectricityEmssnFctrSet.LocBasedGeothermalMixPct)

    Calculations

    Location-Based Electricity from Geothermal (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × ElectricityEmssnFctrSet.Location-Based Geothermal Mix Percentage/100

  • Location-Based Electricity from Other Fossil Fuel (kWh) (LocBsdElectrOthrFossilFuelKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Emissions Factor Set.Location-Based Other Fossil Fuel Mix Percentage (ElectricityEmssnFctrSet.LocBasedOtherFossilFuelMixPct)

    Calculations

    Location-Based Electricity from Other Fossil Fuel (kWh) = Total Fuel Consumption (kWh) (where FuelType = "Electricity") × ElectricityEmssnFctrSet.Location-Based Other Fossil Fuel Mix Percentage/100

  • Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Allocated Energy Attribute Credits from Biomass (kWh) (AllocEnrgyAttrCrBiomass)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Biomass Mix Percentage (MarketBasedBiomassMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Biomass Mix Percentage (MarketBasedBiomassMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
      • Stationary Asset Energy Use (StnryAssetEnergyUseId)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)
    • Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Biomass (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctr.Market-Based Biomass Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Biomass Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Biomass (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctr.Market-Based Biomass Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Biomass Mix Percentage))

      else 0

  • Market-Based Electricity from Coal (kWh) (MktBasedElectrFromCoalInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Coal Mix Percentage (MarketBasedCoalMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Coal Mix Percentage (MarketBasedCoalMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Coal (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Coal Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Coal Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Coal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Coal Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Coal Mix Percentage))

      else 0

  • Market-Based Electricity from Gas (kWh) (MktBasedElectrFromGasInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Gas Mix Percentage (MarketBasedGasMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Gas Mix Percentage (MarketBasedGasMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)
      • Stationary Asset Energy Use (StnryAssetEnergyUseId)
    • Energy Attribute Certificate Credit (EnergyAttrCertCredit)
    • Energy Attribute Certificate Purchase (EnergyAttrCertPurchase)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Gas (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Gas Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Gas Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object,

      if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Gas (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Gas Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Gas Mix Percentage))

      else 0

  • Market-Based Electricity from Hydro (kWh) (MktBasedElectrFromHydroInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Hydroelectric Mix Percentage (MarketBasedHydroMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Hydroelectric Mix Percentage (MarketBasedHydroelectricMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Hydro (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Hydro Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Hydro Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Hydro (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Hydro Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Hydro Mix Percentage))

      else 0

  • Market-Based Electricity from Nuclear (kWh) (MktBasedElectrFrNuclearInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Nuclear Mix Percentage (MarketBasedNuclearMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Nuclear Mix Percentage (MarketBasedNuclearMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Nuclear (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Nuclear Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Nuclear Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Nuclear (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Nuclear Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Nuclear Mix Percentage))

      else 0

  • Market-Based Electricity from Oil (kWh) (MktBasedElectrFromOilInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Oil Mix Percentage (MarketBasedOilMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Oil Mix Percentage (MarketBasedOilMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Oil (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Oil Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Oil Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Oil (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Oil Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Oil Mix Percentage))

      else 0

  • Market-Based Electricity from Other Fuel (kWh) (MktBasedEnrgyFromOthrFuelInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Other Fuel Mix Percentage (MarketBasedOtherFuelMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Other Fuel Mix Percentage (MarketBasedOtherFuelMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Other Fuel (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fuel Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Other Fuel Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Other Fuel (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fuel Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Other Fuel Mix Percentage))

      else 0

  • Market-Based Electricity from Solar (kWh) (MktBasedEnrgyFromSolarInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Allocated Energy Attribute Credits from Solar (kWh) (AllocEnrgyAttrCrSolar)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Solar Mix Percentage (MarketBasedSolarMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Solar Mix Percentage (MarketBasedSolarMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Solar (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Solar Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Solar Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Solar (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Solar Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Solar Mix Percentage))

      else 0

  • Market-Based Electricity from Wind (kWh) (MktBasedEnrgyFromWindInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Allocated Energy Attribute Credits from Wind (kWh) (AllocEnrgyAttrCrWind)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Wind Mix Percentage (MarketBasedWindMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Wind Mix Percentage (MarketBasedWindMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Wind (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Wind Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Wind Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Wind (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Wind Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Wind Mix Percentage))

      else 0

  • Market-Based Electricity from Non-Renewables (kWh) (MktBsdEnrgyFrNonRenewablesKwh)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Market-Based Electricity from Biomass (kWh) (MktBasedElectrFrBiomassInKwh)
    • Market-Based Electricity from Hydro (kWh) (MktBasedElectrFromHydroInKwh)
    • Market-Based Electricity from Solar (kWh) (MktBasedElectrFromSolarInKwh)
    • Market-Based Electricity from Wind (kWh) (MktBasedElectrFromWindInKwh)
    • Market-Based Electricity from Geothermal (kWh) (MktBsdElectrFrGeothermalInKwh)

    Calculations

    Market-Based Electricity from Non-Renewables (kWh) = Total Fuel Consumption (kWh) – Market-Based Electricity from Biomass (kWh) – Market-Based Electricity from Hydro (kWh) – Market-Based Electricity from Solar (kWh) – Market-Based Electricity from Wind (kWh) – Market-Based Electricity from Geothermal (kWh)

  • Market-Based Electricity from Geothermal (kWh) (MktBsdEnrgyFromGeothermalInKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Allocated Energy Attribute Credits from Geothermal (kWh) (AllocEnrgyAttrCrGeothermal)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmssnFctrSet)
      • Market-Based Geothermal Mix Percentage (MktBasedGeothermalMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type = "Geothermal", then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100 + Allocated Renewable Energy (kWh)
    • If Renewable Energy Type ! = "Geothermal" && !Empty, then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Renewable Energy (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100
    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type == Empty (None), then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Energy Attribute Credits (kWh)] × ElectricityEmssnFctrSet.Market-Based Geothermal Mix Percentage/100 + Allocated Energy Attribute Credits from Geothermal (kWh)
    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Geothermal Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Geothermal Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Geothermal (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Geothermal Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Geothermal Mix Percentage))

      else 0

  • Market-Based Electricity from Other Fossil Fuel (kWh) (MktBsdElectrOthrFossilFuelKwh)

    Input Fields

    • Stationary Asset Energy Use (StnryAssetEnrgyUse)
      • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
      • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
      • Renewable Energy Type Override (RenewableEnergyType)
      • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
      • Allocated Energy Attribute Credits from Geothermal (kWh) (AllocEnrgyAttrCrGeothermal)
      • Fuel Type (FuelType)
    • Electricity Emissions Factor Set (ElectricityEmissionFactorsId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Other Fossil Fuel Mix Percentage (MktBasedOtherFossilFuelMixPct)
    • Market-Based Electricity Emissions Factors (MktBsdElectriEmssnFctrId)
      • Emissions Factor Type (EmissionsFactorType)
      • Market-Based Other Fossil Fuel Mix Percentage (MktBasedOtherFossilFuelMixPct)
    • Energy Attribute Credit Distribution (EnergyAttrCreditDstr)

    Calculations

    • If Renewable Energy Type Override ! = Empty, then Market-Based Electricity from Other Fossil Fuel (kWh) = [Total Fuel Consumption (kWh) (where Fuel Type = "Electricity") – Allocated Renewable Energy (kWh)] × (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fossil Fuel Mix Percentage)

      else if (Electricity Emissions Factors == LocationAndMarketBased or –None– (Electricity Emissions Factor Set.Market-Based Other Fossil Fuel Mix Percentage))

      else 0

    • When the renewable energy allocation is happening from the Energy Attribute Credit Distribution object, if Renewable Energy Type Override == Empty (None), then Market-Based Electricity from Other Fossil Fuel (kWh) = [Total Fuel Consumption (kWh) (where FuelType = "Electricity") – Allocated Energy Attribute Credits (kWh)]× (if Market-Based Electricity Emissions Factors != Empty (MktBsdElectriEmssnFctrId.Market-Based Other Fossil Fuel Mix Percentage)

      else if (ElectricityEmissionFactorsId.Emissions Factor Type == LocationAndMarketBased or None (ElectricityEmissionFactorsId.Market-Based Other Fossil Fuel Mix Percentage))

      else 0

  • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)

    Input Fields

    • Allocated Energy Attribute Credits from Biomass (kWh) (AllocEnrgyAttrCrBiomassNumber)
    • Allocated Energy Attribute Credits from Geothermal (kWh) (AllocEnrgyAttrCrGeothermalNumber)
    • Allocated Energy Attribute Credits from Solar (kWh) (AllocEnrgyAttrCrSolarNumber)
    • Allocated Energy Attribute Credits from Wind (kWh) (AllocEnrgyAttrCrWind)

    Calculations

    Allocated Energy Attribute Credits (kWh) = Allocated Energy Attribute Credits from Biomass (kWh) + Allocated Energy Attribute Credits from Geothermal (kWh) + Allocated Energy Attribute Credits from Wind (kWh) + Allocated Energy Attribute Credits from Solar (kWh)

  • Scope 3 Downstream Emissions (tCO2e) (Scope3DnstrmEmissionsIntCO2e)

    Input Fields

    • Other Emissions Factors (OtherEmissionFactors)
    • Supplemental Scope 3 Downstream Emissions (SuplScope3DnstrmEmissions)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    If Carbon Emission Scope Allocation value is one of these values

    • Scope 3 Downstream
    • Scope 3 Downstream Leased Assets
    • Scope 3 End-of-Life Treatment of Sold Products
    • Scope 3 Franchises
    • Scope 3 Investments
    • Scope 3 Processing of Sold Products
    • Scope 3 Use of Sold Products

    or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation value is one of these values

    • Scope 3 Downstream
    • Scope 3 Downstream Leased Assets
    • Scope 3 End-of-Life Treatment of Sold Products
    • Scope 3 Franchises
    • Scope 3 Investments
    • Scope 3 Processing of Sold Products
    • Scope 3 Use of Sold Products

    (where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type)

    If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

    Note

    Then see the calculations for Scope 1 Emissions (tCO2e)

    Default Value

    Scope3DnstrmEmissionsIntCO2e = SuplScope3DnstrmEmissions

  • Scope 3 Upstream Emissions (tCO2e) (Scope3UpstrmEmissionsInTco2e)

    Input Fields

    • Other Emissions Factors (OtherEmissionFactors)
    • Supplemental Scope 3 Upstream Emissions (SuplScope3UpstrmEmissions)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    If Carbon Emission Scope Allocation value is one of these values

    • Scope 3 Upstream
    • Scope 3 Capital Goods
    • Scope 3 Employee Commuting
    • Scope 3 Fuel and Energy-Related Activities
    • Scope 3 Purchased Goods and Services
    • Scope 3 Upstream Leased Assets
    • Scope 3 Waste Generated In Operations

    or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation value is one of these values

    • Scope 3 Upstream
    • Scope 3 Capital Goods
    • Scope 3 Employee Commuting
    • Scope 3 Fuel and Energy-Related Activities
    • Scope 3 Purchased Goods and Services
    • Scope 3 Upstream Leased Assets
    • Scope 3 Waste Generated In Operations

    (where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type)

    If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

    Note

    Then see the calculations for Scope 1 Emissions (tCO2e)

    Default Value

    Scope 3 Upstream Emissions (tCO2e) = Supplemental Scope 3 Upstream Emissions

  • Scope 3 GHG Category (Scope3GhgCategory)

    Input Fields

    • Carbon Emissions Scope Allocation (CrbnEmssnScopeAlloc)
    • Stationary Asset Environmental Source (StnryAssetEnvrSrcId)
      • Carbon Emissions Scope Allocation (CrbnEmssnScopeAllocId)

    Calculations

    If Carbon Emission Scope Allocation value is one of these values

    • Scope 3 Purchased Goods and Services
    • Scope 3 Capital Goods
    • Scope 3 Processing of Sold Products
    • Scope 3 Upstream Leased Assets
    • Scope 3 Fuel and Energy-Related Activities
    • Scope 3 Employee Commuting
    • Scope 3 End-of-Life Treatment of Sold Products
    • Scope 3 Waste Generated In Operations
    • Scope 3 Use of Sold Products
    • Scope 3 Downstream Leased Assets
    • Scope 3 Investments
    • Scope 3 Franchises

    then

    Scope 3 GHG Category = CrbnEmssnScopeAllocVal.FuelTypeAllocation

    or if Carbon Emission Scope Allocation = NULL then StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type Allocation value is one of these values

    • Scope 3 Purchased Goods and Services
    • Scope 3 Capital Goods
    • Scope 3 Processing of Sold Products
    • Scope 3 Upstream Leased Assets
    • Scope 3 Fuel and Energy-Related Activities
    • Scope 3 Employee Commuting
    • Scope 3 End-of-Life Treatment of Sold Products
    • Scope 3 Waste Generated In Operations
    • Scope 3 Use of Sold Products
    • Scope 3 Downstream Leased Assets
    • Scope 3 Investments
    • Scope 3 Franchises

    (where StnryAssetEnvrSrc.Carbon Emission Scope Allocation.Fuel Type = Fuel Type)

    then

    Scope 3 GHG Category = StnryAssetEnvrSrc.CrbnEmssnScopeAllocId.FuelTypeAllocation

    If the scope isn't specified in either the energy use or the asset records, Net Zero Cloud allocates a default scope based on the fuel type and asset ownership. See How to Override the Default Scope Allocation.

    Note

    else

    Scope 3 GHG Category = null

  • CH4 Emissions (kg) (Ch4EmissionsInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)

      Fuel Type (FuelType)

      CH4 Emissions Factor (Ch4EmissionFactor)

    • Electricity Emission Factor Set (ElectricityEmssnFctrSet)

      CH4 Emissions Rate (tonnes/GWh) (Ch4EmissionRateInTgwh)

    Calculations

    If Fuel Type = "Electricity"

    • CH4 Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.CH4 Emissions Rate (tonnes/GWh) × 1000/1000000.0

    Default = 0

    For any fuel other than refrigerants and electricity

    • If CH4 Emissions Factor is in energy units

      CH4 Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.CH4 Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.CH4 Emissions Factor is converted to Kg/Kwh

    • else CH4 Emissions (kg) = 0
  • CO2 Emissions (kg) (Co2EmissionsInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)

      Fuel Type (FuelType)

      CO2 Emissions Factor (Co2EmissionFactor)

    • Electricity Emission Factor Set (ElectricityEmssnFctrSet)

      CO2 Emissions Rate (tonnes/MWh) (Co2EmissionRateInTmwh)

    Calculations

    If Fuel Type = "Electricity"

    • CO2 Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.CO2 Emissions Rate (tonnes/MWh) × 1000/1000.0

    Default = 0

    For any fuel other than refrigerants and electricity

    • If CO2 Emissions Factor is in energy units

      CO2 Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.CO2 Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.CO2 Emissions Factor is converted to Kg/Kwh

    • else CO2 Emissions (kg) = 0
  • N2O Emissions (kg) (N2oEmissionsInKg)

    Input Fields

    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Fuel Type (FuelType)
    • Other Emissions Factor Set (OtherEmssnFctrSet)
    • Other Emissions Factor Set Item (OtherEmssnFctrSetItem)

      Fuel Type (FelType)

      N2O Emissions Factor (N2oEmissionFactor)

    • Electricity Emission Factor Set (ElectricityEmssnFctrSet)

      N2O Emissions Rate (tonnes/GWh) (N2oEmissionRateInTgwh)

    Calculations

    If Fuel Type = "Electricity"

    • N2O Emissions (kg) = Total Fuel Consumption (kWh) × ElectricityEmssnFctrSet.N2O Emissions Rate (tonnes/GWh) × 1000/1000000.0

    Default = 0

    For any fuel other than refrigerants and electricity

    • If N2O Emissions Factor is in energy units

      N2O Emissions (kg) = Total Fuel Consumption (kWh) × OtherEmissionFactor.OtherEmssnFctrSetItem.N2O Emissions Factor where Fuel Type = OtherEmissionFactor.OtherEmssnFctrSetItem.Fuel Type and OtherEmissionFactor.OtherEmssnFctrSetItem.N2O Emissions Factor is converted to Kg/Kwh

    • else N2O Emissions (kg) = 0
  • Fuel Consumption

    Inputs

    • Occupied Floor Area (OccupiedFloorArea)
    • Occupied Floor Area Unit (OccupiedFloorAreaUnit)
    • Other Emission Factors (OtherEmissionFactors)
    • Refrigerant Leakage Rate (kg/sqft) (RefrigerantLeakageRtInKgSqft)

    Calculations

    If (Fuel Type = "Refrigerant") and Fuel Consumption is NULL

    then

    Fuel Consumption = Occupied Floor Area (converted to sqft) × OtherEmissionFactors.Refrigerant Leakage Rate (kg/sqft)

  • Scope 3 CH4 Emissions from Fuel and Energy-Related Activity (Kg) (Scp3Ch4EmssnFuelEnrgy)

    Inputs

    • Fuel Type (FuelType)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Other Lifecycle Emission Factor Set (OthrLifecyclEmssnFctrSetId)
      • Other Lifecycle Emission Factor Set Item (OthrLifecyclEmssnFctrSetItem)
        • Well-To-Tank CH4 Emissions Factor (Well2TkCh4EmssnFctr)
        • Well-To-Tank CH4 Emissions Factor Unit (Well2TkCh4EmssnFctrUnit)
        • Transmission and Distribution CH4 Emissions Factor (TrnsmDstrCh4EmssnFctr)
        • Transmission and Distribution CH4 Emissions Factor Unit (TrnsmDstrCh4EmssnFctrUnit)
        • Well-To-Tank Transmission and Distribution CH4 Emissions Factor (Well2TkTrnsmCh4Emssn)
        • Well-To-Tank Transmission and Distribution CH4 Emissions Factor Unit (Well2TkTrnsmCh4EmssnUnit)

    Calculations

    If Fuel Type = "Refrigerant" or Fuel Type = "Electricity", then Scope 3 CH4 Emissions from Fuel and Energy-Related Activity (Kg) = 0.

    For any fuel other than refrigerants and electricity, Scope 3 CH4 Emissions from Fuel and Energy-Related Activity (Kg) = Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank CH4 Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank CH4 Emissions Factor Unit) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution CH4 Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution CH4 Emissions Factor Unit ) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution CH4 Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution CH4 Emissions Factor Unit)

  • Scope 3 CO2 Emissions from Fuel and Energy-Related Activity (Kg) (Scp3Co2EmssnFuelEnrgy)

    Inputs

    • Fuel Type (FuelType)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Other Lifecycle Emission Factor Set (OthrLifecyclEmssnFctrSetId)
      • Other Lifecycle Emission Factor Set Item (OthrLifecyclEmssnFctrSetItem)
        • Well-To-Tank CO2 Emissions Factor (Well2TkCo2EmssnFctr)
        • Well-To-Tank CO2 Emissions Factor Unit (Well2TkCo2EmssnFctrUnit)
        • Transmission and Distribution CO2 Emissions Factor (TrnsmDstrCo2EmssnFctr)
        • Transmission and Distribution CO2 Emissions Factor Unit (TrnsmDstrCo2EmssnFctrUnit)
        • Well-To-Tank Transmission and Distribution CO2 Emissions Factor (Well2TkTrnsmCo2Emssn)
        • Well-To-Tank Transmission and Distribution CO2 Emissions Factor Unit (Well2TkTrnsmCo2EmssnUnit)

    Calculations

    If FuelType = "Refrigerant" or FuelType = "Electricity", then Scope 3 CO2 Emissions from Fuel and Energy-Related Activity (Kg) = 0

    For any fuel other than refrigerants and electricity, Scope 3 CO2 Emissions from Fuel and Energy-Related Activity (Kg) = Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank CO2 Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank CO2 Emissions Factor Unit ) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution CO2 Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution CO2 Emissions Factor Unit) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution CO2 Emissions × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution CO2 Emissions Factor Unit)

  • Scope 3 N2O Emissions from Fuel and Energy-Related Activity (Kg) (Scp3N2oEmssnFuelEnrgy)

    Inputs

    • Fuel Type (FuelType)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Other Lifecycle Emission Factor Set (OthrLifecyclEmssnFctrSetId)
      • Other Lifecycle Emission Factor Set Item (OthrLifecyclEmssnFctrSetItem)
        • Well-To-Tank N2O Emissions Factor (Well2TkN2oEmssnFctr)
        • Well-To-Tank N2O Emissions Factor Unit (Well2TkN2oEmssnFctrUnit)
        • Transmission and Distribution N2O Emissions Factor (TrnsmDstrN2oEmssnFctr)
        • Transmission and Distribution N2O Emissions Factor Unit (TrnsmDstrN2oEmssnFctrUnit)
        • Well-To-Tank Transmission and Distribution N2O Emissions Factor (Well2TkTrnsmN2oEmssn)
        • Well-To-Tank Transmission and Distribution N2O Emissions Factor Unit (Well2TkTrnsmN2oEmssnUnit)

    Calculations

    If FuelType = "Refrigerant" or FuelType = "Electricity", then Scope 3 N2O Emissions from Fuel and Energy-Related Activity (Kg) = 0

    For any fuel other than refrigerants and electricity, Scope 3 N2O Emissions from Fuel and Energy-Related Activity (Kg) = Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank N2O Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank N2O Emissions Factor Unit) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution N2O Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution N2O Emissions Factor Unit) + Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution N2O Emissions Factor × (conversion factor for kg/kWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution N2O Emissions Factor Unit)

  • Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e) (Scp3EmssnFuelEnrgy)

    Inputs

    • Fuel Type (FuelType)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Electricity Lifecycle Emission Factor Set (ElectrLifecyclEmssnFctrSet)
      • Fuel-Cycle Factor (FuelCycleFactor)
      • Fuel-Cycle Factor Unit (FuelCycleFactorUnit)
      • Lifecycle Transmission and Distribution Factor (LifecyclTrnsmDstrFctr)
      • Lifecycle Transmission and Distribution Factor Unit (LifecyclTrnsmDstrFctrUnit)
    • Other Lifecycle Emission Factor Set (OthrLifecyclEmssnFctrSetId)
      • Other Lifecycle Emission Factor Set Item (OthrLifecyclEmssnFctrSetItem)
        • Well-To-Tank Supplied CO2e Emissions Factor (Well2TkSuplCo2eEmssn)
        • Well-To-Tank Supplied CO2e Emissions Factor Unit (Well2TkSuplCo2eEmssnUnit)
        • Well-To-Tank CO2e Emissions Factor (tCO2e/MWh) (Well2TkCo2eEmssnFctrMwh)
        • Transmission and Distribution Supplied CO2e Emissions Factor (TrnsmDstrSuplCo2eEmssn)
        • Transmission and Distribution Supplied CO2e Emissions Factor Unit (TrnsmDstrSuplCo2eEmssnUnit)
        • Transmission and Distribution CO2e Emissions Factor (tCO2e/MWh) (TrnsmDstrCo2eEmssnMwh)
        • Well-To-Tank Transmission and Distribution CO2e Emissions Factor (tCO2e/MWh) (Well2TkTrnsmCo2eEmssnMwh)
        • Well-To-Tank Transmission and Distribution Supplied CO2e Emissions Factor (Well2TkTrnsmSuplCo2e)
        • Well-To-Tank Transmission and Distribution Supplied CO2e Emissions Factor Unit (Well2TkTrnsmSuplCo2eUnit)
        • Well-To-Tank Transmission and Distribution CO2e Emissions Factor (tCO2e/MWh) (Well2TkTrnsmCo2eEmssnMwh)

    Calculations

    If Fuel Type = "Refrigerant", then Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e) = 0

    If Fuel Type = "Electricity", then Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e) = (Total Fuel Consumption (kWh) × ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor Unit)) / 1000 + (Total Fuel Consumption (kWh) × ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor Unit)) / 1000

    For any fuel other than refrigerants and electricity, Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e) = Well2Tk Component + TrnsmDstr Component + Well2TkTrnsm Component, where:

    Well2Tk Component: If OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Supplied CO2e Emissions Factor = 0 or NULL, then (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank CO2e Emissions Factor (tCO2e/MWh)) / 1000, else (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Supplied CO2e Emissions Factor × (conversion factor for tonnes/MWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Supplied CO2e Emissions Factor Unit )) / 1000

    TrnsmDstr Component: If OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution Supplied CO2e Emissions Factor = 0 or NULL, then (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution CO2e Emissions Factor (tCO2e/MWh)) / 1000, else (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution Supplied CO2e Emissions Factor × (conversion factor for tonnes/MWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Transmission and Distribution Supplied CO2e Emissions Factor Unit)) / 1000

    Well2TkTrnsm Component: If OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution Supplied CO2e Emissions Factor = 0 or NULL, then (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution CO2e Emissions Factor (tCO2e/MWh)) / 1000, else (Total Fuel Consumption (kWh) × OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution Supplied CO2e Emissions Factor × (conversion factor for tonnes/MWh based on OthrLifecyclEmssnFctrSet.OthrLifecyclEmssnFctrSetItem.Well-To-Tank Transmission and Distribution Supplied CO2e Emissions Factor Unit)) / 1000

  • Scope 3 Market-Based Emissions from Fuel and Energy-Related Activity (tCO2e) (Scp3MktEmssnFuelEnrgy)

    Inputs

    • Fuel Type (FuelType)
    • Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e) (Scp3EmssnFuelEnrgy)
    • Renewable Energy Type Override (RenewableEnergyType)
    • Total Fuel Consumption (kWh) (TotalFuelConsumptionInKwh)
    • Allocated Energy Attribute Credits (kWh) (AllocEnrgyAttrCrInKwh)
    • Allocated Renewable Energy Override (kWh) (AllocatedRenewableEnergyInKwh)
    • Electricity Lifecycle Emission Factor Set (ElectrLifecyclEmssnFctrSet)
      • Fuel-Cycle Factor (FuelCycleFactor)
      • Fuel-Cycle Factor Unit (FuelCycleFactorUnit)
      • Lifecycle Transmission and Distribution Factor (LifecyclTrnsmDstrFctr)
      • Lifecycle Transmission and Distribution Factor Unit (LifecyclTrnsmDstrFctrUnit)

    Calculations

    For Fuel Type != "Electricity", Scope 3 Market-Based Emissions from Fuel and Energy-Related Activity (tCO2e) value would be same as Scope 3 Emissions from Fuel and Energy-Related Activity (tCO2e)

    For Fuel Type = "Electricity" - If Renewable Energy Type Override is not empty, then Scope 3 Market-Based Emissions from Fuel and Energy-Related Activity (tCO2e) = ((Total Fuel Consumption (kWh) - Allocated Renewable Energy Override (kWh)) × ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor Unit)) / 1000 + (Total Fuel Consumption (kWh) × ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor Unit )) / 1000, else Scope 3 Market-Based Emissions from Fuel and Energy-Related Activity (tCO2e) = ((Total Fuel Consumption (kWh) - Allocated Energy Attribute Credits (kWh)) × ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Fuel-Cycle Factor Unit)) / 1000 + (Total Fuel Consumption (kWh) × ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor × (conversion factor for tonnes/MWh based on ElectrLifecyclEmssnFctrSet.Lifecycle Transmission and Distribution Factor Unit )) / 1000